3.3.4.

5 Point Calibration

Enter the password RLLR LRLR. The display will respond by showing the number "5". The display will then
1.
begin scrolling the text "SET EMPTY".
2.
Make certain that the tank is EMPTY and then activate the RIGHT switch to store that point. The display will
flash the top two LED rows and then begin scrolling the text "SET 1/4".
3.
Fill the tank to the one-quarter tank point and then activate the RIGHT switch. The display will flash the top
two LED rows and then begin scrolling the text "SET 1/2".
4.
Fill the tank to the one-half tank point and then activate the RIGHT switch. The display will flash the top two
LED rows and then begin scrolling the text "SET 3/4".
5.
Fill the tank to the three-quarter tank point and then activate the RIGHT switch. The display will flash the top
two LED rows and then begin scrolling the text "SET FULL".
6.
Fill the tank to the full point and then activate the RIGHT switch. The display will respond by flashing the top
two LED rows and then start normal operation with the new calibration by displaying FULL (all LEDs on).
3.3.5.
9 Point Calibration
Enter the password RLLR RLLR. The display will respond by showing the number "9". The display will then
1.
begin scrolling the text "SET EMPTY".
2.
Make certain that the tank is EMPTY and then activate the RIGHT switch to store that point. The display will
flash the top two LED rows and then begin scrolling the text "SET 1/8".
3.
Fill the tank to the one-eighth point and then activate the RIGHT switch. The display will flash the top two
LED rows and then begin scrolling the text "SET 1/4".
4.
Fill the tank to the one-quarter point and then activate the RIGHT switch. The display will flash the top two
LED rows and then begin scrolling the text "SET 3/8".
5.
Fill the tank to the three-eighths point and then activate the RIGHT switch. The display will flash the top two
LED rows and then begin scrolling the text "SET 1/2".
6.
Fill the tank to the one-half point and then activate the RIGHT switch. The display will flash the top two LED
rows and then begin scrolling the text "SET 5/8".
7.
Fill the tank to the five-eighths point and then activate the RIGHT switch. The display will flash the top two
LED rows and then begin scrolling the text "SET 3/4".
8.
Fill the tank to the three-quarter point and then activate the RIGHT switch. The display will flash the top two
LED rows and then begin scrolling the text "SET 7/8".
9.
Fill the tank to the seven-eighths point and then activate the RIGHT switch. The display will flash the top two
LED rows and then begin scrolling the text "SET FULL".
10. Fill the tank to the full point and then activate the RIGHT switch. The display will respond by flashing the top
two LED rows and then start normal operation with the new calibration by displaying FULL (all LEDs on).
3.3.6.

Calibration retention

Calibration data is saved in non-volatile memory (EEPROM) and the display does not need power to retain
calibration data.
3.3.7.

Invalid calibration

Calibration automatically makes the ITL40 a MASTER display if the calibration is valid. An invalid calibration is
determined when any calibrated point is not at a higher level than the previous calibrated point, or if the sensor
voltage falls outside of the valid minimum (0.4V) or maximum (4.8V) range.
An invalid calibration is acknowledged by flashing "X" four times and then scrolling the text "CHECK SENSOR
VOLTS" followed by a continuous scroll of the voltage detected on the sensor's signal (pin 6).