Download Print this page

eControls Comfort365 C365C32 Installer Manual

Wiring hub, model wh11 and wh32

Advertisement

Quick Links

Comfort
Optional eLink Radio Module plugs into connectors.
24VAC Power Indicator.
Terminals for wiring
to HVAC equipment.
Terminals for Upstairs wired
temperature sensor.
Terminals for optional outdoor
Description
The Wiring Hub is installed at the equipment. It is connected
to the C365C32 or C365C32WF thermostat using the existing
or new 4-wire thermostat cable that normally connects the
thermostat to the equipment. The equipment is wired directly
to the Wiring Hub. The upstairs sensor can be either a wired
or wireless sensor. Wireless sensors use the ELR1 Radio
Module that plugs into the Wiring Hub. An outdoor
temperature sensor can also be used to control fossil fuel
heating in a dual fuel heat pump (WH32 only).
Compatible Equipment, WH11
Gas/Electric equipment with 1 heat/ 1 Cool.
Compatible Equipment, WH32
Gas/Electric equipment, conventional and dual fuel heat pump
equipment with 3 heat/ 2 Cool.
Power
Powered by 24VAC from the equipment R and C terminals
Warranty
This wiring hub is warranted to be free of defects due to
workmanship or materials under normal use and service for a
period of 5 years from date of installation and not longer than
6 years from manufacturing date code.
365
EQUIPMENT
temperature sensor.
Wiring Hub, Model WH11 and WH32
Cover.
LIVING
SLEEPING
DAMPER
DAMPER
THERMOSTAT
Connector for Upstairs Plug&Play
Modulating Damper.
Connector for Downstairs Plug&Play
Modulating Damper.
Terminals for wiring to
Comfort365 Thermostat.
Power Indicator
LED indicator.
Damper Actuators
Uses A80MJ Plug&Play damper Actuators. Up to 6 dampers
can be daisy chained to define the Upstairs or Downstairs
space.
Wired Upstairs Temperature Sensor
One or two wired sensors can be used in the Upstairs space.
For single sensor installations use TS510W sensor. For two-
sensor installations, use the TS520W sensor.
Wireless Upstairs Temperature Sensor
One or two battery powered, wireless sensors can be used.
The ELR1 Radio Module must be installed in the Wiring Hub
when wireless sensors are used. Use the TS5WL sensor for 1
or 2-sensor installations.
eControls, Inc. 26072 Merit Circle #110 / Laguna Hills, CA 92653
949-916-0945 Fax 949-458-8502 www.eControlsUSA.com
Installer Manual
Ver 2.0 Jun 2017
Screw attaches cover to base.
eControls
eControls

Advertisement

loading

Summary of Contents for eControls Comfort365 C365C32

  • Page 1 This wiring hub is warranted to be free of defects due to workmanship or materials under normal use and service for a eControls, Inc. 26072 Merit Circle #110 / Laguna Hills, CA 92653 period of 5 years from date of installation and not longer than 949-916-0945 Fax 949-458-8502 www.eControlsUSA.com...
  • Page 2 C365C32 Warning - Only use plug and play cable provided with the A80MJ actuator. Additional cables can be ordered through eControls, Model #PIC25 (25 ft.) or PIC50(50 ft)) or directly through the manufacturer - Monoprice, Thermostat Model C365C32 or C365C32WF...
  • Page 3: Temperature Sensor

    Wiring WH11 or WH32 to Upstairs Temperature Sensor Wiring WH11 to Gas/Electric, 1H/1C Use 5-conductor, 18 or 20 gage, thermostat cable to wire the Use 2-conductor, 18 or 20 gage, thermostat cable to wire from the WH11/WH32 Wiring Hub to the upstairs temperature WH11 Wiring Hub to the equipment.
  • Page 4 USING WIRELESS UPSTAIRS SENSORS Setting Wireless Sensors as #1 or #2 Before installing the wireless upstairs temperature sensor, the The TS5WL is factory set as #1 wireless temperature sensor. ELR1 Radio Module needs to be installed in the Wiring Hub. If two upstairs temperature sensors are used, set the address number on the second sensor to #2.

This manual is also suitable for:

Comfort365 c365c32wf