CAN-IB Series XMC and PMC
USER MANUAL
4.01.0310.20000 1.2 en-US ENGLISH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ixxat CAN-IB XMC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for HMS Ixxat CAN-IB XMC Series

  • Page 1 PC CAN Interface CAN-IB Series XMC and PMC USER MANUAL 4.01.0310.20000 1.2 en-US ENGLISH...
  • Page 2 HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous product development. The information in this document shall therefore not be construed as a commitment on the part of HMS Industrial Networks and is subject to change without notice.
  • Page 3: Table Of Contents

    Table of Contents Page User Guide ........................... 3 Target Group........................3 Related Documents ......................3 Document History ......................3 Trademark Information .....................3 Conventions........................4 Safety Instructions ......................5 Information on EMC ......................5 General Safety Instructions ....................5 Intended Use........................5 Scope of Delivery ........................ 5 Features ..........................6 Installation...........................
  • Page 4 10 Disposal..........................14 Regulatory Compliance ..................... 15 EMC Compliance (CE) ..................... 15 FCC Compliance Statement ....................15 4.01.0310.20000 1.2 en-US PC CAN Interface User Manual...
  • Page 5: User Guide

    June 2019 Layout changes, new disclaimer Trademark Information Ixxat ® is a registered trademark of HMS Industrial Networks. All other trademarks mentioned in this document are the property of their respective holders. 4.01.0310.20000 1.2 en-US PC CAN Interface User Manual...
  • Page 6: Conventions

    This is a cross-reference within this document: Conventions, p. 4 This is an external link (URL): www.hms-networks.com Safety advice is structured as follows: Cause of the hazard! Consequences of not taking remediate action.
  • Page 7: Safety Instructions

    Protect product from fire. ► Do not paint the product. ► ► Do not modify or disassemble the product. Service must be carried out by HMS Industrial Networks. ► Store products in dry and dust-free place. Intended Use The interfaces are used to connect computer systems to CAN and LIN networks. They are intended for the installation on carrier cards for use in computer systems with closed housings.
  • Page 8: Features

    Features 6 (16) Features Common Features • active board with 32 bit microcontroller • LIN optional • CAN low-speed (ISO 11898-3) optional • galvanically isolated • common driver interface for easy exchange of PC interface type • XMC according to: –...
  • Page 9: Installing The Hardware

    Installation 7 (16) Installing the Hardware Risk of ESD damages caused by improper handling! Use ESD protective measures to avoid equipment damage. Fig. 1 PC connectors PCIe connector (XMC) PCI connector (PMC) ► Make sure that power is off. ► Plug the PCIe connector (1) resp.
  • Page 10: Connections

    Connections 8 (16) Connections Overview Fig. 2 Connections (XMC) CAN 2 CAN 1 Fieldbus expansion connector channel 1 (option) Fieldbus expansion connector channel 2 PCIe connector (XMC), PCI connector (PMC) CAN Bus The bus coupling can optionally be galvanically isolated. With galvanic isolation the shield of the CAN connector is connected to CAN ground through a 1 MΩ...
  • Page 11: Expansions

    Connections 9 (16) Expansions The fieldbus expansion connectors can be used to extend each CAN circuit with fieldbus expansions for additional fieldbuses (exclusively galvanically isolated interfaces). The signals of the additional fieldbuses are applied to the corresponding CAN connector. 4.01.0310.20000 1.2 en-US PC CAN Interface User Manual...
  • Page 12: Expansions

    Expansions 10 (16) Expansions Fieldbus Expansion Fig. 3 Fieldbus expansion If there is a low-speed CAN transceiver on the fieldbus expansion, it is possible to switch via software between the high-speed CAN transceiver on the interface and the low-speed CAN transceiver on the fieldbus expansion.
  • Page 13: Multican Expansion

    Expansions 11 (16) ► Plug the expansion in the corresponding expansion connector. ► Make sure that the expansion is properly inserted in the socket. → Interface detects installed expansions automatically. If the expansion is not detected automatically, check if the expansion is properly inserted. ►...
  • Page 14 Expansions 12 (16) 7.2.1 Installation Observe different pin allocation of D-Sub-9 connector when using the MultiCAN expansion. Fig. 6 CAN interface with MultiCAN-PB expansion CAN 2/4 CAN 1/3 MultiCAN-PB Fieldbus expansion connectors Install the expansion (see Installation, p. 10). ► Observe different pin allocation of D-Sub-9 connector.
  • Page 15: Technical Data

    Technical Data 13 (16) Technical Data PC address range Plug & Play Interrupts Plug & Play Microcontroller 32 bit microcontroller Dimension Approx. 74 x 149 mm Operating temperature -20 °C to +70 °C Galvanic isolation 1 kV for 1 second CAN-IB210/XMC CAN interface 2 CAN interfaces;...
  • Page 16: Support/Return Hardware

    14 (16) Support/Return Hardware Support/Return Hardware Observe the following information in the support area on www.ixxat.com: • information about products • FAQ lists • installation notes • updated product versions • updates Support For problems or support with the product request support at www.ixxat.com/support. ►...
  • Page 17: A Regulatory Compliance

    Phone +1 312 829 0601 Any changes or modifications not expressly approved by HMS Industrial Networks could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.
  • Page 18 © 2019 HMS Industrial Networks Box 4126 300 04 Halmstad, Sweden info@hms.se 4.01.0310.20000 1.2 en-US / 2019-06-18 / 13689...