Starrett PKG08806-UMDFG User Manual

Starrett PKG08806-UMDFG User Manual

Dfg digital force gage

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PKG08806-UMDFG and is the answer not in the manual?

Questions and answers

Summary of Contents for Starrett PKG08806-UMDFG

  • Page 2: Mapping Softkey

    ANTES DE UTILIZAR EL INSTRUMENTO, LEA ATENTAMENTE ESTE MANUAL LIRE CE MANUEL AVANT D'UTILISER L'INSTRUMENT LEIA ATENTAMENTE ESTE MANUAL ANTES DE UTILIZAR O INSTRUMENTO 使用仪器前请阅读本操作手册 DIESES HANDBUCH VOR DER VERWENDUNG DES MESSGERÄTS LESEN LEGGERE ATTENTAMENTE QUESTO MANUALE PRIMA DI UTILIZZARE QUESTO STRUMENTO 2 PKG08806-UMDFG...
  • Page 3 DFG DIGITAL FORCE GAGE USER MANUAL PKG08806-UMDFG 3...
  • Page 4: Table Of Contents

    Peak Compression Display 5.6.3 Using Filter 4.2.4 Tolerance Display 5.6.4 About Display 4.2.5 Statistics Display 5.6.5 Using a Passcode 4.2.8 Memory Display 5.6.6 Selecting Display Language 4.2.9 Overload Condition Display DFG Force Gage Accessories 4.2.10 About Display Cable Pinout 4 PKG08806-UMDFG...
  • Page 5: General Safety Precautions

    To ensure reproduction of this EMC performance, connect this equipment Starrett will repair or replace, at its option, any part or parts found to to a low impedance ground connection. Typical suitable connections are be defective in workmanship or material.
  • Page 7 DFG DIGITAL FORCE GAGE THIS IS A STARRETT USER GUIDE FOR THE DFG DIGITAL FORCE GAGE. ALL SPECIFICATIONS IN THIS DOCUMENT ARE CORRECT AT TIME OF PRODUCTION AND ARE SUBJECT TO CHANGE. PLEASE CONTACT STARRETT FOR FURTHER INFORMATION. PKG08806-UMDFG 7...
  • Page 8: Introduction

    1600 45,000 0.024 0.60 M6 x 1-6H SPK-FG-S DFG-200 1000 0.021 0.54 M6 x 1-6H SPK-FG-M DFG-500 2500 0.028 0.70 M10 x 1.5-5H SPK-FG-L NOTES Load measurement accuracy is ±0.2% of load cell capacity. Display resolution is 5,000:1. 8 PKG08806-UMDFG...
  • Page 9: Force Gage Fundamentals

    MODE function to the key. Pressing the key can change the operating modes of the gage. You can switch from Real Time to Peak Tension by pressing Softkey 2. Shown: Keypad mapping with display in NORMAL format PKG08806-UMDFG 9...
  • Page 10: Display Layout

    Real Time value Real time load being placed on load cell 0.00 21.06 16.89 Compression Direction 21.10 16.84 Compression Direction Shown: Real Time view showing Peak Compression Real Time Mode Indicator Shown: Peak Compression view Peak Compression Mode Indicator 10 PKG08806-UMDFG...
  • Page 11: Primary Display

    "outside" the tolerance range. The sound is configured in SETUP and may be a "beep", "Chirp" or "Tone". 112.40 91.85 84.93 5.66 5.71 112.40 91.85 Tensile Direction 104.22 Out-of-Tolerance Result 112.40 91.85 PKG08806-UMDFG 11...
  • Page 12: Softkey Labels

    UNITS OF MEASURE The units of measure is displayed with the associated result. Load results may use ozf, gf, lbf, kgf, or N. Distance results may use in (inch) or mm (millimeter). Units User Flip Display View Units of Measure 12 PKG08806-UMDFG...
  • Page 13: Usb Cable (Part No. L1-Usb)

    On the back side of the force gage is an alignment bushing. This bushing fits over the alignment pin on the mounting block to ensure proper gage alignment. SPK-FG-BLOCK Force Gage Mounting Block Force Gage Mounted on MTL-110 Test Frame PKG08806-UMDFG 13...
  • Page 14: Load Sensor Measurement

    Starrett including platens, vise-action grips, wedge- action grips, peel grips, pneumatic grips, roller grips and more. Starrett can supply hundreds of different style grips for virtually any force measurement application. And Starrett can design, engineer, and manufacture custom grips and test fixtures to your exact requirements.
  • Page 15: Force Gage Operation

    When the force gage is in PEAK TENSION MODE, the force gage will display the following: 1 Min Peak/Max Tension Real Time value 5 Min 19.24 15 Min 30 Min 22.29 Auto Off Setup Option Tensile Direction (See Setup for more information) Shown: Peak Tension view Peak Tension Mode Indicator PKG08806-UMDFG 15...
  • Page 16: Peak Compression Display

    When results are saved to memory, the force gage will display the following for the saved results: 5.66 5.71 60.79 50.59 50.59 60.79 45.398 55.69 22.699 σ Peak Tension Mode Indicator Shown: Peak Tension view with Tolerance result Results Saved to Memory 16 PKG08806-UMDFG...
  • Page 17: Overload Condition Display

    • Last Calibration Date with WinWedge software. Use the Send function to export a result to WinWedge on a computer connected to the DFG Force Gage. • Overload History 500 N | 100 lb Firmware 00.02.07 Battery % Overloads About Display PKG08806-UMDFG 17...
  • Page 18: Managing Gage Memory

    UP your results Press q to navigate DOWN your results Clear Press to DELETE a result Go Back Memory Display Clear Export 60.79 50.59 50.59 60.79 45.398 Memory Setup- Display Saved Results 55.69 22.699 σ 18 PKG08806-UMDFG...
  • Page 19: Force Gage Setup

    The secondary display shows the PEAK TENSION or PEAK COMPRESSION Password values achieved during the real time measurement. Language The REAL TIME MODE is depicted by this symbol: English Deutsch Español 0.00 Português 16.89 Français Italiano Chinese 16.84 Russian Polski Czech Real Time Mode Display PKG08806-UMDFG 19...
  • Page 20: Peak Compression Mode

    Select DISPLAY to view memory and Statistics 19.24 Press u Select CLEAR to erase ALL results from Memory Press u Select EXPORT results to an external Device Press t Move out of MEMORY 22.29 Peak Tension Display 20 PKG08806-UMDFG...
  • Page 21: Display Memory

    50.59 50.59 60.79 45.398 55.69 Export Memory Setup 22.699 σ 124.35 124.35 Display Memory view Press the X softkey to delete the highlighted result. Press the Back softkey to move out of the Display Memory view. SEND Softkey PKG08806-UMDFG 21...
  • Page 22: Tolerance

    Move out of LIMIT 2 Sound None Press t Move out of TOLERANCE Limit 1 10.00 Tolerance Enabled Limit 2 20.00 Tolerance Setup Menu Tolerance Enabled Limit 1 10.00 Limit 2 20.00 Sound None Tolerance Limit Setup 22 PKG08806-UMDFG...
  • Page 23: Sounds

    The center Softkey is always mapped to the SETUP MENU. This softkey Keys cannot be mapped to any other function. Softkey 1 Keys Send Sound None Units Softkey 1 Send Save Softkey 2 Mode Mode Stats Softkey Setup Menu PKG08806-UMDFG 23...
  • Page 24: Settings

    Communicate with a serial printer Communicate with a serial external computer or hard drive Printers Computers Network RS232 Cable For Communications (p/n L1-RS232) L1-USB Cable For Charging, Exporting Data and Uploading New Features Computers Printers FMM Test Frame 24 PKG08806-UMDFG...
  • Page 25: Using Usb

    USB device, such as a personal computer RS-232 Setup Menu or external drive. NOTE There is no setup required when using USB 2.0. RS-232 can be used separately and in addition to Bluetooth and USB. ® PKG08806-UMDFG 25...
  • Page 26: 5.6.1.3 Transmit Compression - Sign

    Data Channel Data Channel RS-232 115200 RS-232 115200 Xmit Comp - Xmit Comp - Xmit Units Xmit Units Xmit TOL Xmit TOL Settings Settings Comms Comms Xmit Comp - Xmit Units None Xmit Comp - Transmit Units Setup 26 PKG08806-UMDFG...
  • Page 27: 5.6.1.5 Transmit Tolerances

    Settings Press t Move out of COMMS Comms Settings Display Comms Filters 20.0 Data Channel About RS-232 115200 Password Xmit Comp - Language English Xmit Units Xmit TOL Display Setup Menu Settings Comms Xmit TOL Transmit Tolerance Setup PKG08806-UMDFG 27...
  • Page 28: 5.6.2.1 Using Auto Off

    Backlight Flip Display Normal Flip Display Normal Radix Period Radix Period Settings Settings Display Backlight Display Auto Off 5 Min 15 Min 30 Min 60 Min Settings Display Backlight Display Automatic Power Off Setup 100% Display Backlight Adjustment 28 PKG08806-UMDFG...
  • Page 29: 5.6.2.3 Using Flip Feature

    Flip Display Normal Radix Period Settings Display Flip Display Setup Radix Settings Period Display Comma Flip Display Flip Normal Settings Normal Display Setup Display Settings Radix Display Period Flip Display Comma Flip Normal Flip Display Setup Radix Setup Menu PKG08806-UMDFG 29...
  • Page 30: Using Filter

    Memory Tolerance Filters Softkey 1 Units Softkey 2 Mode Data Channel RS-232 RS-232 115,200 1000 Xmit Comp - Xmit Units Xmit TOL Auto Off 5 Minutes Backlight Flip Display Normal Radix Period Password Language English Filters Setup Menu 30 PKG08806-UMDFG...
  • Page 31: Using A Passcode

    The gage will display "Settings Locked". setup menu. Your Starrett representative will provide you with your Passcode. If a Password is enabled, the user is required to enter the Passcode. Only users with the Pass Code can access the force gage menu and options.
  • Page 32: Selecting Display Language

    DFG FORCE GAGE ACCESSORIES The force gage will display terms in the following languages. To select Starrett can supply all types of testing fixtures, grips and accessories for the desired display language, go to SETUP MENU>LANGUAGES. Select your force measurement systems and instruments. We can also design the language from the list.
  • Page 33 MLX-CLEVIS-FA-M6 Clevis Adapter, Stainless Steel MLX-CLEVIS-FS-M6 Clevis Adapter, Stainless Steel MLX-CLEVIS-FS-M10 Locking Ring, Aluminum MLX-RING-A Locking Ring, Stainless Steel MLX-RING-S Grip Pin, Aluminum MLX-PIN-A Grip Pin, Stainless Steel MLX-PIN-S Spanner Wrench L1-SPANNER Cable, RS-232, 6 ft. (2m) L1-RS232 PKG08806-UMDFG 33...
  • Page 34: Cable Pinout

    Thread B Thread B CABLE PINOUT Pin Number (Male) Wire Color Signal Name Pin Number (Female) Black OUT_0 Brown TX_OUT RX_IN Orange External voltage In (5-24V) NC Yellow Green IN_1 Blue VCC(+5V) 125ma Violet OUT_1 Grey VCC_IN L1-RS232 Cable 34 PKG08806-UMDFG...
  • Page 35 NORTH AMERICA WWW.STARRETT.COM ATHOL, MA, USA, 01331-1915 EUROPE & ASIA WWW.STARRETT.CO.UK JEDBURGH, SCOTLAND, TD8 6LR SOUTH & CENTRAL AMERICA WWW.STARRETT.COM.BR 13306-900, ITU, SP, BRASIL CNPJ 56.994.700/0001-01 CHINA WWW.STARRETT.COM.CN USER MANUALS AVAILABLE ONLINE AT STARRETT.COM...

Table of Contents