Page 1
CC-31 (UK) JAV-1069 (EU) CC-141 (UK) JAV-1065 (EU) CC-231 (UK) JAV-1067 (EU) CC SERIES VACCUM PUMP Safety Instructions & Operation Manual Instructions de sécurité et notice d’utilisation Sicherheitsanweisungen und Bedienungsanleitung Instrucciones de seguridad y manual de funcionamiento Istruzioni di sicurezza e manuale d’uso...
Page 2
CC SERIES VACCUM PUMP Thank you for purchasing a JAVAC product. Please read this operation manual carefully before use. Only suitably qualified personnel should operate this equipment. CONTENTS 1.0 APPLICATION 2.0 PUMP COMPONENTS 3.0 BEFORE STARTING 4.0 TROUBLE SHOOTING 5.0 GUARANTEE 1.0 APPLICATION...
Switch Sight Glass Oil Tank Board Oil Drain Base Motor Fan Cover Plate MODEL CC-31 CC-141 CC-231 VOLTAGE 110 V / 240 V 50 Hz FREE AIR DISPLACEMENT 1.4 / 40 5.3 / 140 9, 225 (CFM / L/M) ULTIMATE VACUUM...
Page 4
3.0 BEFORE STARTING Add vacuum pump oil and always check the oil level before use. Low oil level or poor quality oil will result in premature wear and poor performance. Install on a flat surface with adequate ventilation; allow 5cm on all sides of the pump. Remove the intake and exhaust fitting cap and connect via a suitable hose to a manifold or suitable circuit.
4.13 Foreign matter falling in the pump Check and eliminate the foreign matter DIFFICULT 4.14 Low voltage Avoid long extension leads STARTING 4.15 Overheated Check fan, ventilation and repair 4.16 Safety if in any doubt Consult JAVAC...