13. Quick Start Tutorial

This section will describe how to get started with associated software and set up a basic system for operation.

13.1. Network setup

13.1.1. Network connections / topology

Each frame has two network ports; a primary and a secondary. See the below diagram for a typical network
topology using the primary ports.
By default, the secondary ports are confi gured in dual redundancy mode to support a second redundant network.
The alternate confi guration for the two ports is a switch mode which allows daisy-chaining devices in a single
network. Daisy chain mode is not recommended for more than a few devices, and for not more than two if running
Dante audio along with control data.
Switch
Note: If using Dante audio in the network, the audio traffi c needs to be fi ltered from reaching the
wireless links.
13.1.2. Network confi guration
Frames are confi gured by default to obtain IP addresses automatically. The frame will assign itself an IP address
in the link local range (169.254.1.0 through 169.254.254.255). If a computer is confi gured the same way
(which should be default on modern operating systems), it will reside in the same subnet as the devices and
communication can be established. Alternate confi gurations would be DHCP for a managed network or fi xed IP.
To connect to the secondary network in dual redundancy mode the computer shall be confi gured with an IP
address in the 172.31.0.0 - 172.31.255.255 range.
Computer
Access Point
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
Wireless
Switch
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ SERIES Quick Start Guide rev 3.0.2
13. Quick Start Tutorial
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plm 20k44Plm 12k44Plm 5k44

Table of Contents