Switching On The Device; A Magnetism Detection - Horotec Magtest MSA 19.910 Manual

Table of Contents

Advertisement

Press the ON/OFF button located at the rear panel of the device to turn it on.
The following screen displays :
<->
MAGTEST
DETECT
DEMAG
A. Magnetism detection
DETECT
1. Press the
key on the main menu
movement or any other watch piece).
The following screen displays :
DETECT
DEMAG
0 µT
The search for magnetic remanence is active.
If the displayed value is greater than «0 μT», it is recommended to reset the sensors.
A2. Sensors
There are 5 sensors and one of them is located in the centre of the detection surface. The others are in the corners of a 1.5
cm square. They can measure the magnetism force as well as the position. A dot on the LCD screen shows a sensor with its
position and the dot size is proportional to the magnetic force.
10.

SWITCHING ON THE DEVICE

Display of the main menu
MAGTEST
Display of the submenu
To check the degree of magnetism of small parts (screws for example), it is recommended to
place them in the white areas of the example shown here. The sensor placed in the centre and
the two zones between the 3 outer circles (in red) will not detect the degree of magnetism
of the small parts.
MAGTEST
to check the degree of magnetization of the object (watch,
DETECT
see paragraph 10D4
9

Advertisement

Table of Contents
loading

Table of Contents