  • Page 3: The Magnetic Field

    THE MAGNETIC FIELD A magnetic field is manifested by a force affecting certain materials in its environment, acting on moving electrical charges. The magnitude of this force decreases as a function of the distance between the magnetic field emitter and its action point. Magnetization is a vector quantity which characterizes on a macroscopic scale the magnetic behaviour of a material sample.
  • Page 4: Description

    DESCRIPTION The HOROTEC© MAGTEST is an electronic device for the detection of magnetism in μTesla (μT), demagnetization and control of magnetic remanence of watches, movements, tools and watch parts. It combines the measurement function with the demagnetization function in a single device.
  • Page 5: Connections

    Note : change the battery if the «low battery» symbol appears on the screen when the device is turned on. Battery cover The HOROTEC© Magtest is delivered with an adapter (input 115 - 230 V AC / output 12 V DC), a 9 V battery and instructions for use.
  • Page 6: Settings

    PARAMETERS 1. Mute : silent mode or sound mode. see paragraph 10D2 2. Info : hardware and software version. see paragraph 10D3 INFO 3. Reset : sensors resetting. see paragraph 10D4 4. Auto : activate or deactivate the automatic mode. The object can be moved from the DETECT ZONE to the AUTO DEMAG DEMAG ZONE without having to press the key...
  • Page 7: Functions

    FUNCTIONS <-> DEMAG DETECT DEMAG <-> <-> MAGTEST DEMAG DETECT DEMAG DETECT DEMAG < > DETECT DEMAG 0 µT < > DETECT DEMAG 200 µT...
  • Page 8: Settings

    SETTINGS <-> <-> MAGTEST SETTINGS AUTO DETECT DEMAG INFO <-> <-> COMPASS INFO Hardware Version : V1.3 Software Version : V1.2 +20.1 °C <-> <-> COMPASS RESET SAVE SAVE 360° <-> RESET SAVE...
  • Page 9: Switching On The Device

    SWITCHING ON THE DEVICE Press the ON/OFF button located at the rear panel of the device to turn it on. The following screen displays : <-> MAGTEST DETECT MAGTEST Display of the main menu DEMAG A. Magnetism detection MAGTEST DETECT 1.
  • Page 10 Place the object to be tested on the DETECT ZONE surface. - If the screen remains neutral (as in the image above), it means that the object placed on the detection surface is not magnetized - If red dots appear on the screen and a positive value in μT (as shown in the image below), it means that the object placed on the detection surface is magnetized.
  • Page 11: B Demagnetization

    B. Demagnetization (without going through the DETECT function) MAGTEST DEMAG B1. Press the key on the main menu to demagnetize the object. The following screen displays : <-> DEMAG DEMAG Display of the submenu DETECT DEMAG B2. Place the object to be demagnetized on the demagnetizing surface DEMAG ZONE and press the DEMAG key.
  • Page 12: C Compass Mode

    C. Compass mode The compass mode allows the following checks : - The north of the device corresponds to the actual magnetic north - Check the accuracy of watches equipped with a compass. Compass calibration is rarely necessary unless there is too much gap between the device and the actual magnetic north. Follow the instructions below to calibrate the compass.
  • Page 13: D Settings

    D. Settings D1. Press the to set the device. The following screen displays : <-> SETTINGS AUTO INFO SETTINGS Display of the submenu mode Pressing the key, the symbol will disappear (silent mode) or appear (sound mode). MAGTEST Press the key to return to the main menu INFO mode...
  • Page 14 mode Press the key to check the hardware and software version of the device. The following screen displays : <-> RESET RESET Display of the submenu before resetting SAVE SAVE Press the key to perform the reset. The following screen displays : <->...
  • Page 15 AUTO mode AUTO Press the key to activate or deactivate this function. The following screen displays : <-> SETTINGS AUTO AUTO Display of the submenu INFO AUTO Press the key to deactivate the automatic mode. The symbol disappears. AUTO Press again the key to reactivate the automatic mode.
  • Page 16: Important Information

    The maximum value that can be displayed by the device is 999 μT. The maximum value that can be supported by the sensors before deterioration is 100.000 μT. HOROTEC© is a registered trademark in Switzerland, the United States, the European Union and several other countries.
  • Page 17: Safety Precautions

    Copyright law protects the contents of this operating manual. Law prohibits reproduction and using its elements without the written consent of the manufacturer and the importer. Before you use the HOROTEC© Magtest product, read all operating instructions because it can provide optimum performances and longer service life for your device. Save all manuals and documentation for future reference.
  • Page 18 Handling of the HOROTEC© Magtest : WARNING ! Never use the device near flammable or explosive gases. Stop using the product immediately if you notice any unusual odours, noise, or smoke around it. Do not leave the device in places where it may be subject to extremely high temperatures.