6) After 10 minutes, push the ice switch on the operation panel.
7) Press the push lever/dispense switch, and check for proper ice dispensing action.
8) The ice dispenser stops the ice making process automatically in 1 hour or so when the storage bin is filled with ice, and
restarts when ice is used.
Note: Soggy and sticky ice may be produced depending on water conditions.

2. DISPENSING ICE

1) Select your dispensing choice by pushing ice switch, ice & water switch, or water switch on the operation panel (factory
adjusted to ice & water). The selected switch lights up.
2) Position a container, and dispense a desired amount of ice and/or water.
[DCM-60/120KE]
Ice and/or water keeps being dispensed while the push lever is pressed.
[DCM-60/120KE-P]
Ice and/or water keeps being dispensed while the dispense switch is held down, or a preset amount is dispensed when the
dispense switch is pressed once (portion control).

3. FRONT COVER

The front cover is equipped with a safety device. When the front
cover is removed, the ice switch, ice & water switch, and water switch
flash and no dispensing action is available.
After accessing the control panel for adjustments, replace the front
cover in its correct position.
To prevent damage to the magnet provided inside, do not drop the front
cover from a height.
1) To remove, hold the notches on both sides of the front cover, and pull it
toward you.
2) To replace, hold both sides of the front cover, insert the hooks into the
holes, and securely attach it to the magnet catch.

4. PORTION CONTROL

Pushing the portion control switch on the control panel activates the preset
portion control for ice and/or water dispensing. The portion control is
deactivated in the default setting.
The amount of ice dispensed in the portion control depends on water quality
and storage bin level. The amount of water dispensed in the portion control
depends on water pressure.
Model
Default Setting
DCM-60KE
Ice:
40g
DCM-120KE
Water: Not adjustable
DCM-60KE-P
Ice:
40g
DCM-120KE-P
Water: 120mL
[a] Activating portion control
1) Remove the front cover.
2) Press the portion control switch on the control panel. The display illuminates "PORTION".
NOTICE
Adjustable Range
Ice:
20 - 990g (in 10g steps)
Water: Not adjustable
Ice:
20 - 990g (in 10g steps)
Water: 20 - 990mL (in 10mL steps)
Notch (both
sides)
Front Cover
Front Cover
Front Cover
8
2
Hook
1
Magnet
Catch
Hole (two)