Advertisement

5. INSTALLATION

Incorrect installation can cause harm to people, animals or other items, for which the manufacturer cannot be held
responsible.
Keep the adjustable leg height within 0 to 15 mm to prevent reduction in leg strength or injury caused by a falling adjuster.
* Place the ice dispenser on a firm level surface at counter top height.
* Turn the leg adjusters to level the unit in both the left-to-right and front-to-rear directions
(tilt limit: within 1 cm).

6. ELECTRICAL CONNECTIONS

To prevent possible severe electrical shock to individuals or extensive damage to the unit, the icemaker must be connected
via the flexible supply cord supplied with the icemaker to an appropriate outlet socket installed in accordance with local codes
and regulations i.e. AS / NZS 3000.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
* It is recommended that these appliances are connected to a separate 240VAC supply, protected by an appropriate circuit
breaker and Residual Current Device. Check the nameplate on the icemaker for the supply requirements.
* The main control box fuse is rated at 5A and should only be replaced by a qualified service engineer.
* The service of a licensed electrician may be required to ensure the installation is in accordance with the local codes and
regulations.
* The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live

7. WATER SUPPLY AND DRAIN CONNECTIONS

* The service of a licensed plumber may be required to ensure the installation is in accordance with the local codes and
regulations.
[Connection to the water supply]
* The connections to the mains water supply must be made in accordance with the Plumbing Code of Australia and in
accordance with AS / NZS 3500.1 and AS / NZS 3500.2. This appliance incorporates backflow protection complying with AS /
NZS 3500.1. No further backflow protection is required for connection to the water supply.
* To avoid performance reduction or malfunction caused by scaling, the water supply should have a hardness of not more
than 50 mg/L and a silica content of not more than 30 mg/L. Otherwise, installation of a proper water treatment device will be
required.
* Water supply pressure should be minimum 0.05 MPa (0.5 bar) and maximum 0.78 MPa (8 bar). If the pressure exceeds 0.78
MPa (8 bar), use a proper pressure reducing valve. Do NOT throttle back the supply tap.
* Attach the angle end of inlet hose to the G3/4 fitting at the bottom of the ice dispenser as indicated. It is a wise precaution to
have a stop valve within easy reach.
* Be sure to use the new inlet hose-sets supplied with the appliance. Do not reuse any other inlet hose-set.
* Ensure rubber tap washers are correctly positioned. Hand tighten the inlet hose sufficiently to provide a leak free joint.
CAUTION
WARNING
THIS APPLIANCE MUST BE EARTHED
WARNING
Connect to potable cold water supply only.
5
ENGLISH
Leg
Adjuster
Longer
Shorter