Introduction The Digital MacroView System consists of a digital otoscope head and a USB Video Cable. A 3.5 volt Welch Allyn power source and a computer are necessary to use the Digital MacroView System. Current available Digital MacroView versions: •...
(DFU). A copy of the DFU is available on this website. A printed copy of the DFU can be ordered from Welch Allyn for delivery within 7 calendar days. Product identifier Reorder number Type BF applied part...
Page 7
Directions for use Digital MacroView Agency certifications CERTIFIED TO: CAN/CSA STD C22.2 NO. 601.1 CONFORMS TO: UL STD 60601-1 IEC 60601-1 The CE mark on this product indicates that it has been tested to and conforms with the provisions noted within the 93/42/ EEC Medical Device Directive.
WARNING This product generates and records reference images from inputs obtained from the Welch Allyn Digital Macroview. These reference images are not intended for diagnostic purposes. Cautions A caution statement in this manual identifies a condition or practice, which if not corrected or discontinued immediately, could lead to equipment failure, equipment damage, or data loss.
Page 9
Damage to the system will occur if alternate power sources are attached to the video head. Caution Do not use the Digital MacroView if you notice any signs of damage to the components of the system. Contact Customer Service Department for immediate assistance.
Page 10
2 minutes and off-time a minimum of 10 minutes. Caution Only accepts Welch Allyn specula. Caution Use only Welch Allyn approved lamps. Caution Do not apply alcohol, chemicals, or water to the lenses. Solution entering the optical assembly could...
Align the cutouts in the otoscope head base with power source lugs. Push down slightly and turn 90° clockwise. To remove, reverse this procedure. The otoscope head fits all 3.5v Welch Allyn power sources. Cutout Caution Only accepts Welch Allyn specula.
Operation Welch Allyn Setup Prior to using the Digital MacroView for the first time, install the Welch Allyn Viewer Utility following the instructions provided with the Viewer CD. The software can also be found on the Welch Allyn Website at http://www.welchallyn.com/en/service-support/software-...
Directions for use Digital MacroView 3. Double-click the Welch Allyn Viewer icon on your computer desktop. 4. Turn the power source to FULL ON position to achieve optimum performance. The computer displays an image. Digital MacroView automatically optimizes the image brightness.
Operation Welch Allyn Using the controls Press and hold either function button for Capture: approximately 1 second. Upon release of the function button the image freezes as a thumbnail on the screen. If the image is rotated (see below) then the captured image is rotated.
Directions for use Digital MacroView Reviewing images Snapshot: Click to take a snapshot from the viewer. Image displays as a thumbnail on the screen. Record Video Clip: Click to start recording (green icon); click again to stop recording (blue icon). Video clip displays as a thumbnail on the screen and marked as Video.
Operation Welch Allyn Standby Mode The Digital MacroView shuts down the active viewing window after approximately 12 hours of continuous connection to the active viewing window and computer. To restart the Digital MacroView: Press either function button and re-open Windows Explorer.
Directions for use Digital MacroView Using the throat illuminator The Welch Allyn Digital MacroView can transform into a throat illuminator. While using the throat illuminator there are no images available on screen or for capture. WARNING It is important to note that while the throat...
Protect lamp surface against abrasions and scratches. Use protective eyeglasses when handling. Dispose of lamp with care. Caution Only use Welch Allyn lamp REF 06500-U. Caution Lamps may be hot. Allow the lamps to cool before removing. Caution Avoid removing the lamp for reasons other...
Page 20
Use a fully-charged 3.5v power source. Connect the head to the computer and turn the power to the full on position see “Using the Digital MacroView system” on page 8. 2. Shine the light on a piece of white paper approximately 3.2 cm (1.25”) away.
Directions for use Digital MacroView Cleaning recommendation Caution Do not apply alcohol, chemicals, or water to the lenses. Solution entering the optical assembly could damage internal components. Use a dry cloth to clean the Digital MacroView System monthly.
Electronic and Electrical Equipment (WEEE). If this product is contaminated, this directive does not apply. For more specific disposal information, see www.welchallyn.com/weee, or contact Welch Allyn Customer Service. Outside the EU When the product and its components reach end of life, recycle it locally according to national, state, and local regulations, or return it to Welch Allyn.
Welch Allyn Service policy All repairs on products under warranty must be performed or approved by Welch Allyn. Unauthorized repairs will void the warranty. In addition, whether or not covered under warranty, any product repair shall exclusively be performed by Welch Allyn certified service personnel.
Specifications Item Specification Weight Approximately 95 g (0.2 lb) Dimensions Height: 7.0 cm (2.8 inches) (approximate) Length: 10.2 cm (4.0 inches) Width: 3.7 cm (1.5 inches) Rating Lamp: 3.5Vdc, 810 mA USB: 5.0Vdc, 150 mA Protection against ingress of IPXØ water Operating conditions Temperature...
2) the date specified in the warranty registration card that we ask you to send to us, or 3) the date of purchase of product from the authorized Welch Allyn distributor as documented from a receipt from said distributor.
Page 28
Limited Warranty Welch Allyn Digital MacroView...