 This product is for indoor use only. (Do not use it outdoors.)
 Do not leave the product, or use it without globe installed.
 Do not apply excessive force when mounting/removing the globe. Failure to comply will result in damage.
 When removing and installing the globe again, check that there is no gap between the globe and case.
A gap may result in parts falling in or water ingress.
 Use a soft cloth moistened with water to clean the globe or case.
(Do not use thinner, benzine, gasoline or oil.)
 The waterproof sheet must be used before installation.
 This product has a 1mm thick waterproof sheet at the bottom of the case. However, because installation surface
unevenness may cause a lack of waterproofi ng protection, it is recommended to apply sealant between the unit and the
installation surface to maintain waterproof conditions.
 The following requirements are necessary for proper installation:
- Install the signal beacon where excessive vibration is not present.
- lnstall the signal beacon on a sturdy surface.
- Install the signal beacon on a level surface.
 When waterproofi ng, apply a sealing coating onto the nuts on the backside of the installation surface.
Provide a sealant coating around the wire exit hole, or use a Cable Gland.
NE-24A
TYPE
(1) Unlock the globe by holding and rotating it in a counter-
clockwise direction, then lift it up.
(2) Punch-out the mounting holes on the case by drilling
Ø 4.5 holes from the top.
(3) Peel off the adhesive paper from the waterproof sheet
and apply it to the case.
(4) Affi x the product to the installation surface with screws
and nuts.
(Installation screws and nuts are not included with this
product.)
(5) After mounting the case, fi t the globe by aligning the
positioning marks and lock it by rotating in a clockwise.
 Installation Dimension [Unit: mm]
Wire Exit Hole
(Ø 16)
35.5
 When the Cable Gland is used, the hole must be large enough for it to fi t through.
The recommended Cable Gland size is as follows:
screw size: M16 × 1.5; screw length: shorter than 11 mm;
outer diameter: less than 25 mm;
material: plastic. (Tightening torque : 3 N•m)
When the Cable Gland is used: Ø
26
Installation Holes
(2 - Ø 4.5)
M4 screw
(Tightening torque: 0.6 N•m)
Caution
Notice
(1) (5)
(2)
(3)
(4)
Installation Example