Emerson EV3200-2S0002S Manual page 20

Hide thumbs Also See for EV3200-2S0002S:

Advertisement

Parameter
Name
Parameters
F9.00
displayed by
LED
Selection of
parameters
displayed by
F9.01
LED in
stopping status
(blink)
Type of latest
fault
F9.02
Type of
F9.03
second lastest
F9.04
fault
Type of third
lastest fault
Setting range
The display of each parameter is
controlled by a binary bit. "1" for
display:
Bit0: running frequency (Hz)
Bit1: reference frequency (Hz)
Bit2: output voltage (V)
Bit3: output current (A)
Bit4: output torque (%)
Bit5: DC bus voltage (V)
Bit6: Status of input terminal (No
unit)
Bit7: Status of output terminal (No
unit)
Bit8: low digits of pulse of door
position (0 ~ 9999)
Bit9: high digits of pulse of door
position (0 ~ 9999)
0: preset OD frequency (Hz)
1: preset CD frequency (Hz)
2: status of input terminal (no unit)
3: status of output terminal (no
unit)
4: DC bus voltage (V)
5: low digits of pulse counted for
door position (0 ~ 9999)
6: high digits of pulse counted for
door position (0 ~ 9999)
0: no fault record
1: Over-current in Acc process
(E001)
2: Overcurrent in Dec process
(E002)
3: Overcurrent in constant speed
operation (E003)
4: Overvoltage in Acc process
(E004)
5: Overvoltage in Dec process
(E005)
6: Overvoltage in constant speed
operation (E006)
7 ~ 8: Reserved
9: Output phase loss (E009)
10: Reserved
‐ 20 ‐ 
Min.
Default
unit
31
1
(0000011111B)
1
0
1
0