Download Print this page

Start Procedure - weedingtech FoamStream M600 Quick Start Up Manual

Hide thumbs Also See for FoamStream M600:

Advertisement

Foamstream M600 – User manual – English (EU) –16/05/2018 - ISSUE 3

Start procedure

Figure 3 - M600 User Interface
✓ Complete pre-start checks (previous section)
✓ Press and hold priming button on regulator (item 1 in
Figure 3)
✓ Turn fuel switch to OFF position on generator (item 7 in
Figure 3)
✓ Start the generator by turning key (item 6 in Figure 3) in
a clockwise direction by either:
1. Turn key to position E, release to position D when
engine starts
2. Turn key to position D and double press and hold
ON on the remote (Not shown)
✓ Turn the isolator switch (item 2 in Figure 3) to position
A, the PLC screen (item 5 in Figure 3) should illuminate
Press the RESET button (blue button, item 3 in Figure
3), the FAULT indicator goes out and you should see the
screen represented in Figure 4.
5
1
4
3
Figure 4 - Start-up screen of the PLC
✓ Wait a few seconds before requesting air bleed: buttons
1 or 2 in Figure 4.
If you have disconnected the water tank or are starting for
the first time of the day, please use Air bleed Total
If you just took a break or want to perform an additional air
bleed, please select Air bleed Partial
When bleeding the machine, the trigger must be pushed
to allow water to flow out of the lance. Failure to do so will
cause the machine to display a fault message.
✓ Once button 1 or 2 of Figure 4 are pressed the bleed
screen represented in Figure 5 will appear.
2
6

Advertisement

loading