Custom fireplace program, co-linear direct vent gas fireplaces, single sided, ng & propane

Advertisement

Quick Links

www.stellarhearth.com
Custom Fireplace Program
Co-linear Direct Vent Gas Fireplaces
GALAXY SERIES - SINGLE SIDED
Installation and Operating Manual
NG & Propane
appliance.
WHAT TO DO IF YOU SMELL GAS
Stellar Hearth Products
TM
Installer:
Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
®
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the GALAXY Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Stellar Hearth Products GALAXY Series

  • Page 1 Custom Fireplace Program Co-linear Direct Vent Gas Fireplaces GALAXY SERIES - SINGLE SIDED Installation and Operating Manual NG & Propane Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. appliance. WHAT TO DO IF YOU SMELL GAS —...
  • Page 2 INS_CUST UL REV E Page 2...
  • Page 3 TABLE OF CONTENTS Safety Information 25-31 Prepare The Fireplace Framing 10 & 11 32-33 12 & 13 34-35 14-15 B. Flame Appearance Venting 16-24 Maintenance 19 -20 Page 3 16400-7800 GSS REV E...
  • Page 4 1 - SAFETY INFORMATION A. SAFETY ICON DESIGNATIONS IMPORTANT NOTE HOT GLASS WARNING DO NOT CAUTION damage RISK OF FIRE STOP! B. IMPORTANT SAFETY CONSIDERATIONS • • • • • • clothing ignition. • • • Keep burner and control compartment clean. •...
  • Page 5 A. SINGLE SIDED DIMENSIONS [305] 2X 1/2 [13] 2X 1/2 2X 1 25/32 [13] [45] 3 [76] 3 [76] [381] 6 1/8 [156] 2X 5/8 2X 5/8 [16] ACCESS PANEL [16] OUTSIDE LEFT SIDE ACCESS PANEL FRONT AND REAR 6 5/8 [168] [305] SPECIFICATIONS...
  • Page 6 SPECIFICATIONS Propane Model # B-VENT REG PV IN-LINE PV BTU’S ORIFICE ORIFICE 4-SS-2-GL 4X2 SINGLE SIDED 8” 10” RSO12 RSIF160 60,000 (3X) #43 (3X) #55 5-SS-2-GL 5X2 SINGLE SIDED 8” 10” RSO12 RSIF160 80,000 (4X) #43 (4X) #55 6-SS-2-GL 6X2 SINGLE SIDED 10”...
  • Page 7 C. INSTALLATION OVERVIEW D. PLACEMENT CLEARANCE REQUIREMENTS • • • Page 7 16400-7800 GSS REV E...
  • Page 8 3 - PREPARE THE FIREPLACE CAUTION: FIREPLACE IS NOT LOAD-BEARING. NOTE: OTHER CLEARANCES APPLY. ALL CLEARANCES MUST BE MAINTAINED. A. STANDOFF INSTALLATION LOOSEN SCREW AND FOLD STANDOFF REMOVE SECOND SCREW LOOSENED SCREW PIVOT FOLDED STANDOFF Figure 3A.1 AND SECURE STEP 1: Refer to Figure 3A.1 STANDOFFS NAILING FLANGES Figure 3A.3...
  • Page 9 3 - PREPARE THE FIREPLACE B. NAILING TABS Figure 3B.1 Figure 3B.3 STEP 1: Refer to Figure 3B.1 remaining perforated line. Refer to Figure 3B.5 Page 9 16400-7800 GSS REV E...
  • Page 10 of this manual. NOTE: REFER TO DIMENSIONS SECTION FOR ALLOWABLE FINISHING DIMENSIONS REQUIRED TO FIT THE GLASS PANELS INTO THE FIREPLACE. FINISHING MATERIALS MUST NOT OVERLAP THE DIMENSIONS HIGHLIGHTED IN GREEN NOTE: DO NOT THIS INCLUDES THE 3" BLACK TOP AND BOTTOM GLASS TRIM AND ANY PAINTED SIDES ADJACENT TO THE GLASS. INS_CUST UL REV E Page 10...
  • Page 11 SINGLE SIDED NOTE: THE FIREPLACE IS NOT LOAD-BEARING MINIMUM NON-COMBUSTIBLE ZONE OPEN AIR SPACE 6” [25] 1/2” Standoffs 1/2” Standoffs SINGLE SIDED FRAMING DIMENSIONS IMPORTANT FRAMING NOTES: Model # FRAMING SHOULD BE BUILT AFTER THE FIREPLACE IS INSTALLED OR EXTRA CLEARANCE MUST BE PLANNED FOR AT THE INTAKE COLLAR.
  • Page 12 COMBUSTIBLE OR NON-COMBUSTIBLE BACKING MATERIAL (I.E. SHEETROCK) COMBUSTIBLE FACING MATERIAL COMBUSTIBLE FRAMING 6” [152 mm] 6” MINIMUM NON-COMBUSTIBLE ZONE OPEN AIR SPACE TOP OF FIREPLACE 1/2” [12.7] CLEARANCE TO COMBUSTIBLES ON SURFACE 1/2” [12.7 mm] The fireplace ships with standoffs in place to ensure a 1/2” clearance to STANDOFFS 8”...
  • Page 13 COMBUSTIBLE FRAMING COMBUSTIBLE OR NON-COMBUSTIBLE BACKING MATERIAL (I.E. SHEETROCK) COMBUSTIBLE FACING MATERIAL 7” ABOVE TOP OF FIREPLACE 1/2” [12.7] CLEARANCE TO COMBUSTIBLES ON SURFACE 6” [152 mm] The fireplace ships with standoffs in place to ensure a 1/2” clearance to MINIMUM NON-COMBUSTIBLE ZONE combustibles is maintained on the surface.
  • Page 14 6 - GLASS FRAME ASSEMBLY A. GLASS FRAME ASSEMBLY IDENTIFICATION GLASS Upper Groove Quality Suction Cup LOWER FILLER STRIP SITS OVER GLASS CLIPS Lower Groove GLASS CLIP Figure 6B.1 Figure 6A FOLLOW THE INSTRUCTIONS EXACTLY WHEN REMOVING AND INSTALLING GLASS FRAME ASSEMBLY. GLASS ASSEMBLY SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.
  • Page 15 6 - GLASS FRAME ASSEMBLY B. INSTALL GLASS FRAME ASSEMBLY IMPORTANT: PLASTIC GLASS EDGE PROTECTORS U-Shaped Edge Protector See Figure 6B.2 Inner Glass Figure 6B.4. Outer Glass Edge Protectors Figure 6B.3 - Vertical Trim Piece Outer Glass C. REMOVE GLASS FRAME ASSEMBLY Page 15 16400-7800 GSS REV E...
  • Page 16 7 - GAS LINE SPECIFICATIONS GAS LINE CONNECTION Propane Figure 7 GAS AND ELECTRICAL ACCESS LOCATION 8 - VENTING STOP: MAINTAIN ALL CLEARANCES AS STATED IN THIS INSTALLATION MANUAL. Figure 7 INS_CUST UL REV E Page 16...
  • Page 17 8 - VENTING A. APPROVED VENTING STANDARD IN-LINE Model # B-VENT OUTSIDE AIR POWERVENT POWERVENT 4-SS-2-GL 4X2 SINGLE SIDED 8” 10” RSO12 RSIF160 5-SS-2-GL 5X2 SINGLE SIDED 8” 10” RSO12 RSIF160 6-SS-2-GL 6X2 SINGLE SIDED 10” 10” RSO14 RSIF180 7-SS-2-GL 7X2 SINGLE SIDED 10”...
  • Page 18 8 - VENTING D. IN-LINE POWERVENT PREPARATIONS MOTOR INTAKE SIDE OUTLET Figure 8D.1 Figure 8D.3 Silhouette Circle IMPORTANT NOTE: On the exhaust side of the RSIF 180, YOU WILL NEED TO USE AN 8" TO 10" INCREASER NOT INCLUDED WITH FIREPLACE (Figure 8D.5) Increaser 8"...
  • Page 19 8 - VENTING F. VERTICAL TERMINATIONS • • NO SUBSTITUTION IS ACCEPTABLE. • • DO NOT use an additional speed control on this powervent. • You must use the included Capacitor. • • LOCATION CLEARANCES: VENT TERMINAL SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED...
  • Page 20 8 - VENTING Inside Corner Outside Corner Recessed Location A = Combustible 24” (609.6mm) F = Combustible 6” (152mm) = Non-combustible 12” (304.8mm) = Non-combustible 6” (152mm) Balcony Balcony C = Clearance from corner in with perpendicular side wall with no side wall recessed location = Combustible 24”...
  • Page 21 8 - VENTING H. VERTICAL VENT CAP LOCATION AND CLEARANCES ROOF PITCH 1.83 24” MIN (610MM) 24” MIN* (610MM) * = 24” TO A COMBUSTIBLE SIDE WALL 12” TO A NON-COMBUSTIBLE SIDE WALL IMPORTANT: ALL DIMENSIONS ARE FROM THE EDGE OF THE CAP Figure 8H Page 21 16400-7800 GSS REV E...
  • Page 22 8 - VENTING I. ROOF TERMINATION CAP INSTALLATION - WITH AND WITHOUT DAMPER POWERVENT MOUNTING BRACKETS OR DRILL MOUNTING HOLES TO MATCH BASE INSULATION PAD MUST BE CUT IN CENTER TO ACCOMMODATE VENT SIZE MECHANICAL OPTIONAL FLUE DAMPER Roof Termination With Optional Damper Figure 8I.1 POWERVENT MOUNTING BRACKETS...
  • Page 23 8 - VENTING J. WALL TERMINATION - WITH AND WITHOUT DAMPER OPTIONAL MECHANICAL FLUE DAMPER DRILL 1/4” HOLES TO MATCH POWER VENT BASE INSULATION PAD MUST BE CUT IN CENTER TO ACCOMMODATE VENT SIZE USE APPROPRIATE HEAVY DUTY FASTENERS TO SECURE POWER VENT ACCESS PANEL Wall Termination With Optional Damper NEEDED FOR FUTURE...
  • Page 24 8 - VENTING K. OUTDOOR AIR INTAKE Figure 8K.1 CFM Replacement Air Fireplace Fireplace 480 CFM Length 100 ft 90 ft 80 ft 70 ft 60 ft 50 ft 640 CFM 45 ft 35 ft 25 ft 15 ft 5 ft 800 CFM 70 ft 60 ft...
  • Page 25 A. GAS & ELECTRIC ACCESS OPTIONS easy access to service later. Front View Left Side View 3" Gas Access 3" Gas Access 2X 2 27/32" 1 25/32" Electrical Access X2 Electrical Access X2 1 11/16" 1 1/2" 2X 1 19/32" 2 7/32"...
  • Page 26 B. ELECTRIC - AT INSTALL FUNCTION FUNCTION NOTES: 1 120 VAC SW2 LIGHTS 1 120 VAC SW2 LIGHTS 120 VOLT LOOP 2 120VAC SW2 LIGHTS 2 120VAC SW2 LIGHTS 120 VOLT LOOP 3 120VAC SW1 MAIN FLAME 3 120VAC SW1 MAIN FLAME 120 VOLT LOOP 4 120 VAC SW1 MAIN FLAME 4 120 VAC SW1 MAIN FLAME...
  • Page 27 C. ELECTRIC - SERVICE & TROUBLESHOOTING Page 27 16400-7800 GSS REV E...
  • Page 28 INS_CUST UL REV E Page 28...
  • Page 29 Terminals 7 & 8 Page 29 16400-7800 GSS REV E...
  • Page 30 OPTIONAL Flue Damper Connection OPTIONAL NOTE: OPTIONAL IF A DAMPER IS NOT USED DO NOT CONNECT ANYTHING TO TERMINALS 9 & 10 INS_CUST UL REV E Page 30...
  • Page 31 OPTIONAL Flue Damper Connection OPTIONAL NOTE: OPTIONAL IF A DAMPER IS NOT USED TERMINALS 11 AND 12 HAVE A JUMPER ACROSS THEM Page 31 16400-7800 GSS REV E...
  • Page 32 NOTE: REFER TO DIMENSIONS SECTION FOR ALLOWABLE FINISHING DIMENSIONS REQUIRED TO FIT THE GLASS PANELS INTO THE FIREPLACE. FINISHING MATERIALS MUST NOT OVERLAP THE DIMENSIONS HIGHLIGHTED IN GREEN NOTE: DO NOT THIS INCLUDES THE 3" BLACK TOP AND BOTTOM GLASS TRIM AND ANY PAINTED SIDES ADJACENT TO THE GLASS. D - COMBUSTIBLE OR NON-COMBUSTIBLE BACKER MATERIAL (I.E.
  • Page 33 NOTE: REFER TO DIMENSIONS SECTION FOR ALLOWABLE FINISHING DIMENSIONS REQUIRED TO FIT THE GLASS PANELS INTO THE FIREPLACE. FINISHING MATERIALS MUST NOT OVERLAP THE DIMENSIONS HIGHLIGHTED IN GREEN NOTE: DO NOT THIS INCLUDES THE 3" BLACK TOP AND BOTTOM GLASS TRIM AND ANY PAINTED SIDES ADJACENT TO THE GLASS. D - COMBUSTIBLE OR NON-COMBUSTIBLE BACKER MATERIAL (I.E.
  • Page 34 11 - LIGHTING & SHUTDOWN FOR YOUR SAFETY - READ BEFORE LIGHTING • WHAT TO DO IF YOU SMELL GAS: • • Do not try to light any appliance • • • phone • • • department DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE NOTE: A PAINT SMELL WILL OCCUR DURING THE FIRST FEW HOURS OF BURNING.
  • Page 35 11 - LIGHTING & SHUTDOWN B. IF THE FIREPLACE DOES NOT LIGHT accumulated Figure 11B technician or the gas supplier. disappear after several minutes. Page 35 16400-7800 GSS REV E...
  • Page 36 CAUTION: A LOW PRESSURE READING CAN CAUSE DELAYED IGNITION A. INSTALLING THE MEDIA Figure 13A Figure 13A NOTE: DO NOT SUBSTITUTE THE SUPPLIED MEDIA WITH ANY OTHER KIND OF MEDIA WITHOUT WRITTEN APPROVAL OF STELLAR HEARTH PRODUCTS. B. FLAME APPEARANCE INS_CUST UL REV E Page 36...
  • Page 37 VALVE AND ELECTRICAL ACCESS NOTE: INSTALLATION AND REPAIR SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING A. VENT SYSTEM • • INSTALLATION. • B.