Notes (1) The number of flashes when in the service mode do not include the 1.5 second period when the lights light up at first (start signal). (See the ex-
ample shown below.)
RUN light
(10's digit)
OFF
TIMER light
(1's digit)
OFF
Notes
(2) Abnormal Stop:
Notes
(3) Automatic Recovery: - Does not occur.
(d) Wireless remote control information tables
1) Operation switching
Display pattern when
in service mode
RUN light
(Operation switching)
0
1
2
3
4
* If no data are recorded (error code is normal), the information display in the wireless remote control becomes as follows.
Wireless remote control setting
Operation switching
Fan speed switching
(Example): Operation switching, fan speed switching, cooling HI
ON
RUN light
(10's digit)
OFF
ON
TIMER light
(1's digit)
OFF
• In the case of current cut (example: stop code "42")
The RUN light (10's digit) flashes 4 times and the TIMER light (1's digit) flashes 2 times.
4 × 10 + 2 × 1 = 42 → From the table, read the instructions for error code 42, "Current cut".
1.5 sec.
ON
0.5 sec.
0.5 sec.
ON
- Is not displayed. (automatic recovery only)
○ Displayed.
If there is a (
) displayed, the error display shows the number of times that an automatic recovery occurred for the same
reason has reached the number of times in (
If no (
) is displayed, the error display shows that the trouble has occurred once.