Kenwood TKR-D710 Service Manual page 61

Vhf digital base-repeater
Hide thumbs Also See for TKR-D710:
Table of Contents

Advertisement

Item
Condition
18. Test Tone
FPU Test mode
Deviation
1) Adjust Item: [Test Tone De-
adjust
viation (Analog Wide)]
[Analog
Connect the Deviation Meter
Wide]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
19. Test Tone
FPU Test mode
Deviation
1) Adjust Item: [Test Tone De-
adjust
viation (Analog Narrow)]
[Analog Nar-
Connect the Deviation Meter
row]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
20. CW ID
FPU Test mode
Deviation
1) Adjust Item: [CW ID Devia-
adjust
tion (Analog Wide)]
[Analog
Connect the Deviation Meter
Wide]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
21. CW ID
FPU Test mode
Deviation
1) Adjust Item: [CW ID Devia-
adjust
tion (Analog Narrow)]
[Analog Nar-
Connect the Deviation Meter
row]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
22. Courtesy
FPU Test mode
Tone Devia-
1) Adjust Item: [Courtesy Tone
tion adjust
Deviation (Analog Wide)]
[Analog
Connect the Deviation Meter
Wide]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
23. Courtesy
FPU Test mode
Tone Devia-
1) Adjust Item: [Courtesy Tone
tion adjust
Deviation (Analog Narrow)]
[Analog Nar-
Connect the Deviation Meter
row]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
Rear
TX ANT
meter
Oscilloscope
TKR-D710
Adjustment
Parts
Method
PC
3.0kHz Deviation
±0.1kHz
ADJ
Press [Apply] button to store
the adjustment value.
1.5kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
2.0kHz Deviation
±0.1kHz
Press [Apply] button to store
the adjustment value.
1.0kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
1.0kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
0.5kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
Specifi cations / Remarks
61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents