Kenwood TKR-D710 Service Manual page 60

Vhf digital base-repeater
Hide thumbs Also See for TKR-D710:
Table of Contents

Advertisement

TKR-D710
Item
Condition
12. QT Devia-
FPU Test mode
tion adjust
1) Adjust Item: [QT Deviation
[Analog
(Analog Wide)]
Wide]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz, HPF: OFF
De-emphasis: OFF
Detector: p-p/2
Press [Transmit] button.
13. QT Devia-
FPU Test mode
tion adjust
1) Adjust Item: [QT Deviation
[Analog Nar-
(Analog Narrow)]
row]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz, HPF: OFF
De-emphasis: OFF
Detector: p-p/2
Press [Transmit] button.
14. DQT Devia-
FPU Test mode
tion adjust
1) Adjust Item: [DQT Deviation
[Analog
(Analog Wide)]
Wide]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz, HPF: OFF
De-emphasis: OFF
Detector: Peak hold
Press [Transmit] button.
15. DQT Devia-
FPU Test mode
tion adjust
1) Adjust Item: [DQT Deviation
[Analog Nar-
(Analog Narrow)]
row]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz, HPF: OFF
De-emphasis: OFF
Detector: Peak hold
Press [Transmit] button.
16. DTMF
FPU Test mode
Deviation
1) Adjust Item: [DTMF Devia-
adjust
tion (Analog Wide)]
[Analog
Connect the Deviation Meter
Wide]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz, HPF: OFF
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
17 . DTMF
FPU Test mode
Deviation
1) Adjust Item: [DTMF Devia-
adjust
tion (Analog Narrow)]
[Analog Nar-
Connect the Deviation Meter
row]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz, HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
60
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
Rear
TX ANT
meter
Oscilloscope
Adjustment
Parts
Method
PC
0.75kHz Deviation
±0.05kHz
ADJ
Press [Apply] button to store
the adjustment value.
0.35kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
0.75kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
0.35kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
3.0kHz Deviation
±0.1kHz
Press [Apply] button to store
the adjustment value.
1.5kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
Specifi cations / Remarks