Kenwood TKR-D710 Service Manual page 57

Vhf digital base-repeater
Hide thumbs Also See for TKR-D710:
Table of Contents

Advertisement

Item
Condition
5. Low RSSI
FPU Test mode
Adjust
1) Adjust Item [Low RSSI (Ana-
[Analog
log Wide)]
Wide]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low']
[Center], [High'], [High]
Output: –118dBm (0.28µV)
MOD: 1.0kHz
DEV: ±3.0kHz
6. Low RSSI
FPU Test mode
Adjust
1) Adjust Item [Low RSSI (Ana-
[Analog Nar-
log Narrow)]
row]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low']
[Center], [High'], [High]
Output: –118dBm (0.28µV)
MOD: 1.0kHz
DEV: ±1.5kHz
7 . High RSSI
FPU Test mode
Adjust
1) Adjust Item [High RSSI (Ana-
[Analog
log Wide)]
Wide]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low']
[Center], [High'], [High]
Output: –70dBm (70.7µV)
MOD: 1.0kHz
DEV: ±3.0kHz
8. High RSSI
FPU Test mode
Adjust
1) Adjust Item [High RSSI (Ana-
[Analog Nar-
log Narrow)]
row]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low']
[Center], [High'], [High]
Output: –70dBm (70.7µV)
MOD: 1.0kHz
DEV: ±1.5kHz
9. Receiver
1) Connect the SSG to the RX
Sensitivity
ANT.
Check
SSG setting
[Analog
Frequency: Desired Frequency
Wide]
Output: –53dBm (501µV)
MOD = 1.0kHz
DEV: ±3.0kHz
AF: 0.45V/4
[Analog Nar-
2) SSG setting
row]
DEV: ±1.5kHz
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Rear
RX ANT
SSG
Rear
RX ANT
Audio
analyzer
Oscillo-
TEST/
scope
SPKR
Jack pin
12
4 load
TKR-D710
Adjustment
Parts
Parts
PC
Press [Apply] button to store
ADJ
the adjustment value.
PC
Press [Apply] button to store
ADJ
the adjustment value.
Check
–115dBm (0.4µV) or Less
Specifi cations / Remarks
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents