Group 5
0x05
5.2. Supported Command Classes
1
Z-Wave plus Info Version 2
2
Notification Version 8
3
Association Version 2
4
Association Group Info Version 1
5
Transport Service Version 2
6
Version Version 3
7
Manufacturer Specific Version 2
8
Device Reset Locally Version 1
9
Powerlevel Version 1
10
Battery Version 1
11
Security 2 Version 1
12
Supervision Version 1
13
Wake Up Version 2

6. Technical Specifications

Parameters
Dimensions
Weight
Operating Temperature
Max. Humidity
IP Class
Radio frequency
Modulation
Transmission power
Power supply
Battery type
Power consumption standby
Power consumption trigger
Battery-life
Range (open field)
Range (building)
Tamper protection
Firmware updateable
Support Z-Wave Beaming
SmartStart supported
Z-Wave Network Security
Z-Wave AES-128 Security
Z-Wave Plus
2- When the sensor detects status change between close
door and open door, the device will be triggered.
Root Device group(Notification)
1-Binary Sensor reports the removed status of door sensor.
2- When the sensor detects status change of tamper, the
device will be triggered.
Unit
mm
72 x 21 x 26 (Sensor) / 35 x 11 x 13 (Magnet)
g
°C
%
MHz
db
mA
mA
m
m
11
SHMK10000
45
0 – 40
95
20
868,42 (Z-Wave PLUS, Europe)
FSK/GFSK
< 4,5
3 V DC
CR2
0,005
38
3 Years (10 triggers per day)
100
20, related to material of walls
Yes
No
No
No
Yes
Yes
Yes
English