2013.00
Standard bathtub
- Hot water connection for 1/2" tap fittings
- Cold water connection for 1/2" tap fittings
- IPX5 box with PG13.5 - PG9 cable gland
- E
lectrical connection
- A
larm system connection
A - The maximum thickness floor tiles for covering 9mm
ART. 382
Net
Water
Floor
Weight
Content
(1)
Load
Kg/m 2
Kg.
lt.
395
123
280
Art.
K074+Cromoexperience
Top+Hydrosilence+Cromoexperience
(1) - At overflow level
1/2
1/2"
1/2"
"
/
chromotherapy

HYDRAULIC CHARACTERISTICS

Deliv.
Deliv.
Weight
Volume
Jets N.
m 3
Kg.
6
173
1,84
8

OPTIONAL

Installation
V
Mod.
1LDX18
230
2WLI28
PRE-INSTALLATION CARD
Bathtub turned 180°
1/2"
The product has been designed to be installed on masonry walls. If it is neces-
sary to fix it to different types of walls (wood, plasterboard), adequately rein-
force the wall to guarantee a solid fixing.
N.B. Installation must take place once floors and walls are completed.
Hydromassage
Water
Air
Capacity l/m.
Flow l/m.
200
280
300
hydrosilence
Installed Power
Hz
KW
0,09
50
1,4
ART. 382
(mm 1600 x 800)
1/2"

ELECTRICAL CHARACTERISTICS

Whirlpool
Art.
V
Art.
Basic-J
1WBX38
230
Basic-E
1WLX38
TOP+
230
1WLI28
Measurements in mm.
Installed
Power
Hz
kW
0,95
50
1,2
50
1,2
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 382 and is the answer not in the manual?

Questions and answers

Summary of Contents for Teuco 382

  • Page 1 ART. 382 PRE-INSTALLATION CARD (mm 1600 x 800) 2013.00 Bathtub turned 180° Standard bathtub 1/2" 1/2" 1/2" 1/2" Measurements in mm. The product has been designed to be installed on masonry walls. If it is neces- - Hot water connection for 1/2” tap fittings sary to fix it to different types of walls (wood, plasterboard), adequately rein- - Cold water connection for 1/2”...
  • Page 2: Electrical Installation

    S - remote control ART. 382 - Dispenser H = 620 P - Electric Control Panel cap (Ø 50) H = 620 1625 BASIC 69 mm P - Electric Control Panel D - Dispenser (Ø 50) A - Air regulation (Ø 50)

Table of Contents