No: Failure message
99: Extra module 2
102: Clock not running
reserve
105: Maintenance
notification
106: Source temp too low
107: Hot gas, compr. 1
127: Legionella temperature
174:
Malfunctions and alarm
messages
222:Heat pump pressure
223: Heating circuit start-up
pressure
Gebwell Qi Installation, operation, and maintenance manual
Sensor Description
The controller cannot detect the
extra module 2 from the
channel.
The battery on the controller's
operating monitor is running
out.
A maintenance notice is
programmed on the controller.
The incoming temperature from
the collector is lower than set in
the menu. The controller will
restore the situation
automatically in 4 hours.
Alarm goes off, when hot gas
sensor shows 130°C. 3 alarms
per 8 hours are allowed with
automatic restoring.
The heat pump has not been able
to maintain the requested
temperature in the legionella
function. The controller will
retry charging after minimum
idle time.
The electrical resistor's
overheating protector has
tripped.
High pressure switch has
E10
tripped.
High pressure switch has tripped
E10
in connection with the start-up
of heating.
Cause
Measure
Failure in the electrical
Contact a qualified
system
technician.
Failure in the electrical
Contact a qualified
system
technician.
Contact a qualified
technician.
Check that the shut-
off valves on the
collector are open.
Too low flow in the
Check the strainer on
collector.
the collector. If
necessary contact a
qualified technician.
Contact a qualified
technician.
Domestic hot water has
been used during raising
operation.
The resistor has overheated
Check that the
due to a possible lack of
pressure in the
water, a circulation
heating system is
problem, or the presence of
correct > bleed air
air in the system.
from the heating
system.
Open radiator/floor
heating thermostats.
Too low a flow in charging
Vent the heating
/ heat supply circuit.
network. Check the
Radiator or floor heating
network pressure.
valves are shut off or set too
Clean the strainer.
low. Air in the heating
Check that the
system. The heating system
charging pump is
pressures are too low. A
running. If necessary
clogged strainer.
contact a qualified
technician.
Open radiator/floor
heating thermostats.
Too low a flow in charging
Vent the heating
/ heat supply circuit.
network. Check the
Radiator or floor heating
network pressure.
valves are shut off or set too
Clean the strainer.
low. Air in the heating
Check that the
system. The heating system
charging pump is
pressures are too low. A
running. If necessary
clogged strainer.
contact a qualified
technician.
49
Measure
Check the fastening of
the flat cable between
controllers. Check that
the extra module is
connected to power
supply (green light).
Check that the flat cable
is fastened properly both
to the controller and the
display.
Perform annual
maintenance of the
equipment.
Check the functioning of
the collector.
Check the functioning of
the cooling unit.
Acknowledge the alarm
using the button on the
bottom of the resistor.
Check the functioning of
the heat supply network.
Check the functioning of
the heat supply network.