Summary of Contents for Racal Instruments 1260-30 Series
Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 2
PUBLICATION DATE: April 6, 2000 Copyright 1997 by Racal Instruments, Inc. Printed in the United States of America. All rights reserved. This book or parts thereof may not be reproduced in any form without written permission of the publisher.
Page 3
Authorization is required from Racal Instruments before you send us your product for service or calibration. Call your nearest Racal Instruments support facility. A list is located on the last page of this manual. If you are unsure where to call, contact Racal Instruments, Inc. Customer Support Department in Irvine, California, USA at...
Page 4
FOR YOUR SAFETY Before undertaking any troubleshooting, maintenance or exploratory procedure, read carefully the WARNINGS and CAUTION notices. This equipment contains voltage hazardous to human life and safety, and is capable of inflicting personal injury. If this instrument is to be powered from the AC line (mains) through an autotransformer, ensure the common connector is connected to the neutral (earth pole) of the power supply.
Page 5
This page was left intentionally blank. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 6
NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax” section of this manual shows the command syntax for the 1260-01S Smart Card. If you are using the newer 1260-01T Smart Card, the commands will NOT work as shown. Consult the 1260-01T Manual for a description of the commands that may be used with the 1260-01T Smart Card.
Page 7
Control Information for the 1260-30A The following information describes the control-register-to-relay-channel mapping for a 1260-30A Relay Module. This information may be used to control a 1260-30A when using a 1260-01T in the register-based mode of operation. Each relay on this module is controlled by setting or clearing a single bit within a Control Register. Control Registers on the module operate 8 channels simultaneously.
Page 8
Control Information for the 1260-30B The following information describes the control-register-to-relay-channel mapping for a 1260-30B Relay Module. This information may be used to control a 1260-30B when using a 1260-01T in the register-based mode of operation. Each relay on this module is controlled by setting or clearing a single bit within a Control Register. Control Registers on the module operate 8 channels simultaneously.
Page 9
Control Information for the 1260-30C The following information describes the control-register-to-relay-channel mapping for a 1260-30C Relay Module. This information may be used to control a 1260-30C when using a 1260-01T in the register-based mode of operation. Each relay on this module is controlled by setting or clearing a single bit within a Control Register. Control Registers on the module operate 8 channels simultaneously.
Page 10
Control Information for the 1260-30D The following information describes the control-register-to-relay-channel mapping for a 1260-30D Relay Module. This information may be used to control a 1260-30D when using a 1260-01T in the register-based mode of operation. Each relay on this module is controlled by setting or clearing a single bit within a Control Register. Control Registers on the module operate 8 channels simultaneously.
User Manual 1260-30 This page was left intentionally blank. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
User Manual 1260-30 Chapter 1 MODULE SPECIFICATION The 1260-30 Signal/Multiplexer Scanner Module is a 1 X 40 1260-30 Module multiplexer. It switches two lines per channel, and has the Specification capability of being configured as two 1 X 20 matrices, four 1 X 10 matrices or eight 1 X 5 matrices (refer to the diagram in Figure 1- Figure 1-1, 1260-30 Signal/Multiplexer Scanner Module Module Specification 1-1...
User Manual 1260-30 Com 1 Com 2 Com 3 Com 1 Com 4 Com 5 Com 6 Com 7 Com 8 Figure 1-2, 1260-30 Relay Matrix Maximum Switchable Voltage 220VDC, 250VAC RMS Specifications (Terminal-Terminal or Terminal-Chassis Maximum Switchable Current 2A DC or RMS Maximum Switchable Power Per Channel 60W DC, 62.5VA AC...
Contents. Following all NOTES, CAUTIONS, and WARNINGS to ensure personal safety and prevent damage to the instrument. Racal Instruments has a complete Service and Parts Department. Product Support If you need technical assistance or should it be necessary to return your product for servicing, call 1-800-722-3262.
Page 18
User Manual 1260-30 This page was left intentionally blank. Module Specification 1-4 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Series cards. Failure to do so may cause damage to the unit. 1. Use the original packing material when returning the switching Reshipment module to Racal Instruments for servicing. The original Instructions shipping carton and the instrument's plastic foam will provide the necessary support for safe reshipment.
User Manual 1260-30 Installation of the Option 01 into the 1260-30 is described in the Option 01 Installation section of the 1260 Series VXI Switching Cards Installation Manual. Installation of the 1260-30 Switching Module into a VXI mainframe, Module including the setting of DIP switches, is described in the Installation Installation section of the 1260 Series VXI Switching Cards Manual.
User Manual 1260-30 The following connections are required to configure the 1260-30 1260-30A as a 1260-30A. To configure the 1260-30A from any other 1260- 30 configuration, remove all connections not on this list, and install 22 gauge solid jumpers, listed below, unless otherwise specified. COM 01 to E01 COM 22 to E22 COM 51 to E51...
User Manual 1260-30 The following connections are required to configure the 1260-30 1260-30B as a 1260-30B. To configure the 1260-30B from any other 1260- 30 configuration, remove all connections not on this list and install 22 gauge solid jumpers, listed, below unless otherwise specified. COM 01 to E01 COM 22 to E22 COM 51 to E51...
User Manual 1260-30 The following connections are required to configure the 1260-30 1260-30C as a 1260-30C. To configure the 1260-30C from any other 1260- 30 configuration, remove all connections not on this list and install 22 gauge solid jumpers, listed below, unless otherwise specified. COM 01 to E10 COM 31 to E31 COM 61 to E61...
Page 24
User Manual 1260-30 The following connections are required to configure the 1260-30 1260-30D as a 1260-30D. To configure the 1260-30B from any other 1260- 30 configuration, remove all connections not on this list and install 22 gauge solid jumpers, listed below, unless otherwise specified. *COM 01 to E00-1 Teflon stranded, 24 gauge, white COM 02 to E00-2...
User Manual 1260-30 Each configuration of the 1260-30 will respond to different sets of 1260-30 ID Byte values for <group number> and <channel>. The set of values is controlled by switches 5 and 6 on DIP switch S1 on the PCB. The switch settings that correspond to the four configurations are as follows: Model...
Page 26
User Manual 1260-30 This page was left intentionally blank. Installation Instructions 2-8 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
User Manual 1260-30 Chapter 3 MODULE SPECIFIC SYNTAX The Module Specific Syntax for the 1260-30 is required in the use 1260-30 Module of the OPEN and CLOSE commands. It will also appear in data Specific Syntax output by the Master in response to the PDATAOUT and PSETUP commands The Module Specific Syntax for the 1260-30 Signal Syntax...
User Manual 1260-30 The valid values of <group number> and <channel> for the different 1260-30 configurations are as follows: Configuration <channel> <group number>s One 1 x 40 00-39 Two 1 x 20 00-19 Four I x 10 00-09 0,1,2, and 3 Eight 1 x 5 00-04 0,1,2,3,4,5,6, and 7...
User Manual 1260-30 1 260-30C: <module address>. I 260-30C 10-channel Signal Multiplexer/Scanner Module <module address>.BBM <module address>.END I 260-30D: <module address>. 1260-30D 5-channel Signal Multiplexer/Scanner Module <module address>.BBM <module address>.END The response to the PSETUP command consists of a header on the first line.
Page 30
User Manual 1260-30 1260-30D: <module address>. 1260-30D 5-channel Signal Multiplexer/Scanner Module <module ad dress>.<channel>[,<channel [,<channel>] <module address>.END The response to the PDATAOUT command consists of a header on the first line as with the PSETUP response. The next line details the channels currently closed on the module and is blank when no channels are closed.
User Manual 1260-30 Figure 3-2, 1260-30 Configurations and Command Codes (continued) Module Specific Syntax 3-7 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 34
User Manual 1260-30 This page was left intentionally blank. Module Specific Syntax 3-8 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
User Manual 1260-30 Chapter 5 PARTS LIST 404767-001 Final Assembly, 1260-30A..............5-3 404767-002 Final Assembly, 1260-30B..............5-3 404767-003 Final Assembly, 1260-30C ..............5-4 404767-004 Final Assembly, 1260-30D ..............5-4 404938 Shipping Kit, 1260-20 ................5-4 401906 PCB Assy, 1260-20 ................5-5 List of Suppliers....................
Page 64
User Manual 1260-30 This page was left intentionally blank. Parts List 5-2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 65
User Manual 1260-30 Parts List 5-3 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 66
User Manual 1260-30 Parts List 5-4 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 67
User Manual 1260-30 Parts List 5-5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 68
User Manual 1260-30 Parts List 5-6 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 69
User Manual 1260-30 Parts List 5-7 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 70
User Manual 1260-30 This page was left intentionally blank. Parts List 5-8 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
User Manual 1260-30 Chapter 6 OPTIONAL HARNESS ASSEMBLIES The following harness assemblies are used to connect Racal Instruments Model 1260-30 to Freedom Series Test Receiver Interfaces. Each harness documentation consists of an assembly drawing, parts list, system wire list and wire list.
Page 72
User Manual 1260-30 This page was left intentionally blank. Optional Harness Assemblies 6-2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
User Manual 1260-30 Chapter 7 PRODUCT SUPPORT Racal Instruments has a complete Service and Parts Department. Product Support If you need technical assistance or should it be necessary to return your product for repair or calibration, call 1-800-722-3262. If parts are required to repair the product at your facility, call 1-949-859- 8999 and ask for the Parts Department.
User Manual 1260-30 Support Offices Racal Instruments, Inc. 4 Goodyear St., Irvine, CA 92618-2002 Tel: (800) 722-3262, FAX: (949) 859-7309 Racal Instruments, Ltd. 480 Bath Road, Slough, Berkshire, SL1 6BE, United Kingdom Tel: +44 (0) 8706 080134; FAX: +44 (0) 1753 791290 Racal Systems Electronique S.A.
Page 93
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Need help?
Do you have a question about the 1260-30 Series and is the answer not in the manual?
Questions and answers