Main Menus And Submenus Of Settings And Registers - ABB SPAJ 160 C User Manual And Technical Description

Capacitor protection relay
Table of Contents

Advertisement

Main menus and
submenus of
settings and
registers
16
Normal status, display off
Current on phase L1
Current on phase L2
Current on phase L3
Compensated unbalance
current ∆Ic
Starting value setting I
>
b
Multiplier k for I
>
b
Starting value setting I
>
a
Starting value setting I
<
R
E
Reconnection time
V.
setting t
rec
S
T
E
Starting value setting ∆I
>
P
1
.5
s
Starting value setting ∆I
M
>
2
A
I
Unbalance compensation
N
setting ∆I
cs
M
Setting of functional
E
switchgroup SGF
N
U
Setting of blocking
switchgroup SGB1
F
W
D.
Setting of relay
switchgroup SGR1
S
T
E
P
1
s
Latest memorized, event (n)
1
value of phase current IL1
Latest memorized, event (n)
2
value of phase current IL2
Latest memorized, event (n)
3
value of phase current IL3
Duration of latest activation
4
of unit I
a>
Duration of latest activation
5
of unit I
b>
Latest memorized, event (n)
6
value of unbalance ∆I
c
Duration of latest activation
7
of unit ∆I
>
1
Duration of latest activation
8
of unit ∆I
>
2
Duration of latest activation
9
of unit I<
Status of external relay
0
blocking / control signal
Relay unit identification
A
address for communication
Fig 4. Main menus and submenus of the capacitor bank module SPCJ 4D40
MAIN MENU
SUBMENUS
STEP 0.5 s
PROGRAM 1 s
Measured unbalance
1
current ∆I
1
Operating time t
a
1
Operating time t
<
1
Operating time t∆
1
Multiplier k∆
2
1
for ∆I
>
2
Setting of blocking
1
switchgroup SGB2
Setting of relay
1
switchgroup SGR2
Previous event (n-1)
1
value of phase IL1
Previous event (n-1)
1
value of phase IL2
Previous event (n-1)
1
value of phase IL3
Duration of previous
1
activation of unit Ia>
Duration of previous
1
activation of unit I
>
b
Latest memorized event (n)
1
value of unbalance ∆I
Duration of previous
1
activation of unit ∆I
>
1
Duration of previous
1
activation of unit ∆I
>
2
Duration of previous
1
activation of unit I<
0
000
IRF
Ib>start
Ib>trip
Ia>trip
Communication rate
1
setting [kBd]
Setting of blocking
2
switchgroup SGB3
REV. STEP 0.5 s
SUBMENUS
Number of Ia> starts
2
since latest reset
Number of I
> starts
b
2
since latest reset
Previous event (n-1)
2
value of unbalance ∆Ic
Number of ∆I
> starts
1
2
since latest reset
Number of ∆I
> starts
2
2
since latest reset
Number of I< starts
2
since latest reset
∆I1>trip
∆I2>start
∆I2>trip
I<trip
Rec.Inh.
Loss of bus traffic time
Password for
2
3
counter 0..255 s
altering settings
FWD. STEP 1 s
Previous event (n-1)
3
value of unbalance ∆I

Hide quick links:

Advertisement

Table of Contents
loading