5.5. Manual Control / Calibration

Manual pump control group box
Allows you to manually control the various pumps and their calibration.
Pump flow
Depending on the tubing used, you have the option to achieve the following performance:
a) high flow Pharmed/Viton/Santoprene
• Fast flow - maximum average flow 110ml/min
• Moderate flow - maximum average flow 60ml/min
• Precise flow - not suggested (in-regular flow depending from material hardness.
The best for precise dose is silicone tubing.
b) high flow special silicone tube (thick)
• Fast flow - maximum average flow 140ml/min
• Moderate flow - maximum average flow 110ml/min
• Precise flow - maximum average flow 50ml/min
c) precise flow special silicone tube (thin)
• Fast flow - maximum average flow 60ml/min
• Moderate flow - maximum average flow 26ml/min
• Precise flow - maximum average flow 10ml/min (!)
There are three modes to choose from:
1. Fast flow
2. Moderate flow
3. Precise flow