31.4 Alarm Output Volume

112 +/- 2dB at minimum volume "1" measured at 1 inch (2.54 cm)
117 +/- 2dB at maximum volume "9" measured at 1 inch (2.54 cm)
31.5 Alarm Output Pitch
3000 Hz at minimum pitch "1"
4000 Hz at maximum pitch "9"
31.6 Altitude Selection Interval
10 feet (10 meters)
31.7 Setup Defaults
Altitude Offset:
None
AUT / ECO:
ECO
Beep ON / OFF:
ON
Set Dive Type:
None
TAS / SAS:
TAS
Feet / Meters:
Feet
Celsius / Fahrenheit:
Celsius
MPH / KM/H:
MPH
31.8 Logbook
Minimum freefall time for logbook generation in normal mode:
Around 8 seconds.
Minimum freefall time for logbook generation in "3-Sec mode":
Around 3 seconds.
Approximately 200 jumps with two minute profiles
Approximately 26 jumps with 15 minute profiles
Accumulated number of jumps: 29,999
Max. exit altitude: 30,000 feet (9,140 m)
When Divetype set to SLO: Max exit altitude: 39,999 feet (12,191 m)
Max accumulated freefall time: 999 hours