5.8.5
Exit "Factory Mode"
To exit this mode, push the "VOLUME minus" button on the
TV's local keyboard for 10 seconds (this disables the
continuous mode).
Then push the "SOURCE" button for 10 seconds until to exit the
"Factory mode".
5.8.6

Logging

When something is wrong with the TV set (f.i. the set is
rebooting) you can check for more information via the logging
in Hyperterminal. The Hyperterminal is available in every
Windows application via Programs, Accessories,
Communications, Hyperterminal. Connect a "ComPair UART"-
cable (3138 188 75051) from the service connector in the TV to
the "multi function" jack at the front of ComPair II box.
Required settings in ComPair before starting to log:
- Start up the ComPair application.
- Select the correct database (open file "QFU1X.X", this will set
the ComPair interface in the appropriate mode).
- Close ComPair
After start-up of the Hyperterminal, fill in a name (f.i. "logging")
in the "Connection Description" box, then apply the following
settings:
1. COMx
2. Bits per second = 115200
3. Data bits = 8
4. Parity = none
5. Stop bits = 1
6. Flow control = none
During the start-up of the TV set, the logging will be displayed.
This is also the case during rebooting of the TV set (the same
logging appears time after time). Also available in the logging
is the "Display Option Code" (useful when there is no picture),
look for item "display number xxx" in the beginning of the
logging. Tip: when there is no picture available during rebooting
you are able to check for "error devices" in the logging (LAYER
2 error) which can be very helpful to determine the failure cause
of the reboot. For protection state, there is no logging.
5.8.7

Guidelines Uart logging

Description possible cases:
Uart loggings are displayed:
When Uart loggings are coming out, the first conclusion we
can make is that the TV set is starting up and
communication with the flash RAM seems to be supported.
The Fusion processor is able to read and write in the
DRAMs.
We can not yet conclude: Flash RAM and DRAMs are fully
operational/reliable.There still can be errors in the data
transfers, DRAM errors, read/write speed and timing
control.
No Uart logging at all:
No startup will end up in a blinking LED status: error
LAYER 1 = "2", error LAYER 2 = "53" (startup with SDM
solder paths continuous short).
Error LAYER 2 = "15" (hardware cause) is more related to
a supply issue while error LAYER 2 = "53" (software cause)
refers more to boot issues.
Uart loggings reporting fault conditions, error messages, error
codes, fatal errors:
Some failures are indicated by error codes in the logging,
check with error codes table (see Table
overview"). e.g. => <<<ERROR>>>PLFPOW_MERR.C :
First Error (id=10,Layer_1=2,Layer_2=23).
2
I
C bus errors.
Not all failures or error messages should be interpreted as
fault. For instance root cause can be due to wrong option
codes settings => e.g. "FpgaDimmingPresent: False/True".
Service Modes, Error Codes, and Fault Finding
"5-2 Error code
In the Uart log startup script we can observe and check the
enabled loaded option codes.
Defective sectors (bad blocks) in the Nand Flash can also be
reported in the logging.
Startup in the SW upgrade application and observe the Uart
logging:
Starting up the TV set in the Manual Software Upgrade mode
will show access to USB, meant to copy software content from
USB to the DRAM. Progress feedback can be found in the
logging.
Startup in Jett Mode:
Check Uart logging in Jet mode mentioned as : "JETT UART
READY".
5.8.8
Loudspeakers
Make sure that the volume is set to minimum during
disconnecting the speakers in the ON-state of the TV. The
audio amplifier can be damaged by disconnecting the speakers
during ON-state of the set!
5.8.9
Power Supply
In case of no picture when CSM (test pattern) is activated and
backlight doesn't light up, it's recommended first to check the
LED drivers on the PSL(S) + wiring (LAYER 2 error = 17 is
displayed in SDM).

5.8.10 Display option code

Attention: In case the SSB is replaced, always check the
display option code number (group 2, first option number e.g.
"44855") in SAM, even when picture is available. Performance
with the incorrect display option code can lead to unwanted
side-effects for certain conditions.
Also supported in this chassis:
While in the download application (start up in TV mode + "OK"
button pressed), the display option code can be changed via
062598 HOME XXX special SAM command (XXX=display
option in 3 digits).
back to
div. table
QFU1.1E LA
5.
EN 33