Sio(Rs232) Imi Tech Commands - Imi Tech Mx-xxxxG Series User's Operation Manual

Gige cameras
Table of Contents

Advertisement

AMAZON SERIES Operation Manual
5.5.7.

SIO(RS232) IMI TECH Commands

0xF2F10018
IMI Tech Commands are valid when the Bit30 is set to "0"(zero).
SIO(RS232) IMI Tech commands are a specific mode for IMI cameras.
communication parameters must be set at Serial_Mode_Reg (F2F22000h).
F2F10018 means that the RS232 command is valid.
Baud Rate
57600 bps (default)
Command format : [STX] [Command] [Data] [ETX]
[STX]
Command] : Command length is 2byte. See next page command table.
[Data]
[ETX]
Return value
'G'
"Gdd..Z"
'U'
Valid Character : '0'~'9', 'A'~'F', 'S', 'Z' Any invalid character that is received, is discarded.
(example) Gain setting command with 0x200 value.
All of "SA0200Z", "S A0 200 Z", "SA0 200Z", "S A0200 Z", and "SKA0V200Z" are parsed to "SA0200Z Z", and
"SKA0V200Z" is parsed to "SA0200Z".
P i o n e e r i n D i g i t a l V i s i o n T e c h n o l o g y
Auto-Sync Mode control register
Bit 30: SIO enable mode (0 : IMI-TECH mode, 1)
Stop Bit
1 bit
: Command start character: 'S'
: Data length is varied with each command. Data format is hexadecimal: '0'~'9', 'A'~'F'.
: Command end character: 'Z'
: Command complete acknowledge.
: "Gdd..Z" is return data and a hexadecimal character.
: Undefined command.
Before using these commands, serial
Parity
Flow Control
None
Page 63
Read/Write
Non

Hide quick links: