Trigger And Strobe Signal Relation - Imi Tech Mx-xxxxG Series User's Operation Manual

Gige cameras
Table of Contents

Advertisement

Page 46
Status Control Register
Address
F0F00830h
4.9.2.

Trigger and Strobe Signal Relation

Name
Field
TRIGGER
Presence_Inq
_MODE
Abs_Control
-
ON_OFF
Trigger_Polarity
Trigger_Mode
Parameter
AMAZON SERIES Operation Manual
Bit
Description
Presence of this feature
0
0: N/A, 1: Available
Absolute value control
0: Control with value in the Value field
[1]
1: Control with value in the Absolute value CSR
If this bit = 1, value in the Value field is ignored.
[2..5]
Reserved
Write:
ON or OFF this feature
Read:
read a status
[6]
0: OFF,
1: ON
If this bit=0, other fields will be read only.
If Polarity_Inq is "1",Write to change polarity of the
trigger input Read to get polarity of trigger input
[7]
If Polarity_Inq is "0",Read only.(0: Low active
input, 1: High active input)
[8..11]
Reserved
[12..15]
Trigger mode.(Trigger_Mode_0-15)
[16..19]
Reserved
[20..31]
Parameter for trigger function, if required.
P i o n e e r i n D i g i t a l V i s i o n T e c h n o l o g y

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents