Solder lead wire and lands
(6) 7 lands -- (T301)
(7) 13 lands --(M100)
(8) Brown, Yellow -- (T40)
(9) Black, Red, Orange,
Green -- (T31)
(10) Black -- A105
Gray, Red, Orange, Blue -- T72
7. 0-A3(Bottom plate assy)
(1) When installing 0-A3, arrange the
flex of T901 and lead wires to outside.
(2) TY-CSM1.7x4.0 x 2
(3) CNL-D1.7x2.5 x 2
(4) TY-CNL-D1.7x4.0 x 2
(5) Fix T901 with A65 x 2
(6) CNL-D1.7x2.5 x 2
(7) T81 --- Attached to bottom plate.
(8) Attach A53.
8. [CONF] CCD Base Plate Support Pillar (T600)
[Required equipment] Block gauge for 35mm, Dial gauge comparator, etc. (same as MZ series)
(1) Measure height of the CCD base support pillar (3 places) from the mount surface as shown in
the figure. (There are two kind of height)
(2)
Distinction
Tolerance:
(It is difference from 76180,76450)
Using Block gauge for 35mm
(45.46mm)
Last two digit of lot number
[00 or 01] and
[02] and after with[X] stamp
47.890 ±0.02 mm
+2.430 ±0.02 mm
(+2.410 - 2.450 mm)
76570EM 28