The correspondence readings between temperature measured by fixing thermistor and HEX readings
Temperature
AD value
[C°]
-20
204
-19
202
-18
200
-17
198
-16
196
-15
193
-14
191
-13
189
-12
186
-11
184
-10
181
-9
179
-8
176
-7
174
-6
171
-5
168
-4
166
-3
163
-2
160
-1
158
0
155
1
152
2
150
3
147
4
144
5
141
6
139
7
136
8
133
9
131
10
128
11
125
12
123
13
120
14
117
15
115
16
112
17
110
18
107
19
105
HEX reading
Temperature
[C°]
CC
27
CA
28
C8
29
C6
30
C4
31
C1
32
BF
33
BD
34
BA
35
B8
36
B5
37
B3
38
B0
39
AE
40
AB
41
A8
42
A6
43
A3
44
A0
45
9E
46
9B
47
98
48
96
49
93
50
90
51
8D
52
8B
53
88
54
85
55
83
56
80
57
7D
58
7B
59
78
60
75
61
73
62
70
63
6E
64
6B
65
69
66
AD value
HEX reading
86
56
84
54
82
52
80
50
78
4E
76
4C
74
4A
72
48
70
46
68
44
67
43
65
41
63
3F
61
3D
60
3C
58
3A
57
39
55
37
54
36
52
34
51
33
50
32
48
30
47
2F
46
2E
45
2D
43
2B
42
2A
41
29
40
28
39
27
38
26
37
25
36
24
35
23
34
22
33
21
32
20
31
1F
31
1F
58
Temperature
AD value
[C°]
74
25
75
24
76
23
77
23
78
22
79
22
80
21
81
21
82
20
83
20
84
19
85
19
86
18
87
18
88
17
89
17
90
16
91
16
92
16
93
15
94
15
95
14
96
14
97
14
98
13
99
13
100
13
101
12
102
12
103
12
104
12
105
11
106
11
107
11
108
10
109
10
110
10
111
10
112
10
113
9
HEX reading
19
18
17
17
16
16
15
15
14
14
13
13
12
12
11
11
10
10
10
0F
0F
0E
0E
0E
0D
0D
0D
0C
0C
0C
0C
0B
0B
0B
0A
0A
0A
0A