Smoke Alarm/Safety Tip; Operation - Vermont Castings Montpelier Medium Insert Owner's Manual

Hide thumbs Also See for Montpelier Medium Insert:
Table of Contents

Advertisement

Your Insert's Controls and What They Do
All Montpelier Medium Insert controls are conveniently located
on the front. (Figure 8)
Two controls regulate the performance of your Montpelier
Medium Insert:
The primary air control supplies oxygen for the fire.
The variable-speed fan control, or rheostat, regulates the
warm air flow into the room.
Air Control Lever
Fan Speed Control (Behind louvre)
Figure 8 - Montpelier Medium Insert controls.
Primary Air Control
ST997
A single air control regulates the amount of heat the fire will
monty controls
produce and how long it will burn.
1/08
The primary air control lever is located on the upper left side
on the front of the insert. The lever regulates air for starting,
maintaining, and reviving the fire.
Generally, more air entering the stove makes the fire burn
hotter and faster, while less air prolongs the burn.
!
This wood heater has a manufactured-set minimum low
burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
wood heater in a manner inconsistent with operating
instructions in this manual.
11
Vermont Castings • Montpelier Medium Insert Installation & Operating Manual_R26 • 05/19

Operation

WARNING
The Montpelier Medium Insert's air supply is increased when
the control lever is moved to the left, and decreased when
moved to the right. It may be set anywhere between the
two extremes, depending on the amount of heat desired.
(Figure 9)
To complement the manual setting of the air control, the
Montpelier Medium Insert has an integral convection air
blower that ensures an even delivery of heat at the manual
setting you select.
Air Control Lever
Open - Control Lever to the Left
Closed - Control Lever to the Right
Figure 9 - The air control lever controls the amount of air entering
the firebox.
The Fans
ST1000
The convection fan delivers a steady stream of warm air into
Primary air settings
the room. Use the fan speed control to regulate the flow of air
1/08
into the room. A thermal switch will automatically de-activate
the fan when the stove cools down. When starting a fire in
a cold stove, this switch will typically energize the fan within
about 60 minutes depending on wood species and fuel load.
The fan speed should be set at "low" (fully closed) when
operating at low to medium burn rates and may be set
anywhere between "low" and "high" when operating at high
burn rates. (Refer to Figure 10 for fan access)
3-90-30004403