jablotron JA-62GSM Installation Manual page 6

For gsm
Table of Contents

Advertisement

Event
Partial setting
Lost communication w. device
Power fault of control panel
Control panel power OK
Low battery in the device
Communicator fault
Communicator is working
Back up battery fault
Back up battery OK
Receiver jamming detected
Setting (Two section system)
Unsetting (Two section system)
Setting zone A
Setting zone B
Unsetting zone A
Unsetting zone B
Low SIM card credit
Control panel powering up
Service/maintenance mode
entered
Service/maintenance mode exit
Alarm end
Alarm cancelled by user
All tampers contacts OK
No fault in system
All device power OK
Master code changed
AC fault longer then 30 minutes
PG output ON
PG output OFF
tab. 3 ARC event table
Source
701
Control panel
731
Communicator
741
Keypad
001 - 016
Wired inputs
017 – 032
Wireless detectors
033 - 040
Remote controls
041
Wireless siren
042
Sub panel
500
Master code
599
Service code
501 - 514
Code 1 – code 14
tab. 4 Source number table
The report to the ARC consists of:
− Premises number, event code, section, source number.
− Section: 01 is set for all reports
− Split system for setting and unsetting: 02 = A, 03 = B
− Unsplit system for Partial setting (Home bypassed) : 03
− Unsplit system for Set always (Normal arming): 02
Notes:
− Events to ARC are reported with the identification of the section
7.5. ARC communication checking – periodic or fixed
This sequence is used to define whether the regular transmission takes
place at a given time according to 07 p hhmm, or periodically according to 07
p hhmm settings.
p
where:
1=ARC1, 2=ARC2
x
0 = with a period according to 07 p hhmm
1 = at the set time according to 07 p hhmm
Factory default setting:
With a period after the last report
The JA-62GSM communicator for GSM
The JA-62GSM communicator for GSM
Factory
CID CODE
default
settings
3402
reported
1350/3350
reported
1301
reported
3301
reported
1384/3384
reported
1330
not reported
3330
not reported
1302
reported
3302
reported
1355
reported
3402
reported
1402
reported
3402
reported
3402
reported
1402
reported
1402
reported
*
not reported
3301
not reported
1306
reported
reported
3306
*
not reported
1406
reported
3137
reported
3300
not reported
*
not reported
*
not reported
1301
reported
1661
not reported
3661
not reported
Name
06 p x
7.6. ARC communication checking period
uu
CL
This sequence programs how often the communication check is
performed:
13
12
14
13
15
14
where:
16
15
17
16
18
17
19
18
Notes:
20
19
Checking reports are not sent in service mode.
21
20
Jablotron GPRS protocol allows very frequent checking of ARC
24
21
communication (even every 5 minutes in practice).
30
22
When 00:00 is set, a communication check is not performed.
31
23
Factory default setting:
30
24
7.7. Enable ARC reporting (ARC2 backs up ARC1)
31
25
This sequence allows reporting to ARCs to be switched on/off and also
28
26
enables ARC2 to backup ARC1:
29
27
50
28
64
29
where:
65
30
31
66
Note: if ARC2 backs up ARC1 then it will only receive reports if it is not
possible to deliver them to ARC1. Each event is first reported to ARC1 (both
67
32
main and backup number / URL address) and if the transmission fails, the
78
33
event is reported to ARC2. A report containing "Communication fault to
80
34
ARC1" is then sent to ARC2 together with the first report to ARC2
81
35
Factory default setting:
82
36
86
37
7.8. Recording ARC reporting in the control panel memory
89
38
This sequence enables the recording of every report successfully
92
39
communicated to ARCs in the control panel's internal memory:
93
40
001 0
001 1
Note: it is recommended not to record reports sent to ARCs via reliable
protocols (IP CID and SMS CID) but to enable the indication of ARC
communication faults (see 7.9). This saves a significant amount of control
panel memory. The system initially assumes that every report is successfully
delivered to ARCs, but if a report is not successfully delivered within 110
seconds of transmission, then a communication fault will be indicated and
recorded.
Factory default setting:
7.9. Indicate an unsuccessful ARC communication fault
Enables the indication and recording of a communication fault if a report is
not successfully delivered to an ARC within 110 seconds of its transmission:
002 0
002 1
Notes:
The communicator continues trying to send information to an ARC even
after a communication fault has been indicated (after the data has been
delivered, communication fault indication stops)
for communication-checking reports the delivery time limit (confirmation
from the ARC) is 300 minutes. But if any other report is sent to the ARC it
must be confirmed within 110 seconds (otherwise a communication fault
will be indicated).
Factory default setting:
7.10. Locking the ARC settings
All settings which affect reporting to ARCs can be locked by a digital code.
To do so, enter:
where:
Notes:
Exiting service mode after the locking code has been entered will lock all
the settings affecting ARC communication (see the sequence list in
section 12).
If ARC programming is locked, then it can be temporally enabled in
service mode by entering 092 xx..x F0 where xx..x is the locking code.
It will then relock on exiting service mode.
6 / 11
07 p hhmm
p
1 = ARC1, 2 = ARC2
hh
hours
mm
minutes
23:59 (hours:mins)
08 p x
p
1 = ARC1, 2 = ARC2
x
0 = off, 1 = on, 2 = ARC2 backs up ARC1 (2 can only
be entered for ARC2)
Transmissions to both ARCs are off
disabled
enabled
disabled
communication faults not indicated
communication faults indicated
communication faults not indicated
091 xx..xF0
xx..x
is your code (4 to 8 digits)
MLD52902

Advertisement

Table of Contents
loading

Table of Contents