iBright
CL1500 and FL1500 Imaging Systems
™
Catalog Numbers A43678, A43679, A44114, A44115, A44240, and A44241
Pub. No. 100085108 Rev. A
WARNING!
Read the Safety Data Sheets (SDSs) and follow the handling instructions. Wear appropriate protective eyewear, clothing, and
gloves. Safety Data Sheets (SDSs) are available from thermofisher.com/support.
Set up after unpacking
Once unpacked and installed, power on the imager and follow the touchscreen prompts to set up a network configuration, enter instrument
information, and install the turntable.
Package should include: iBright
Sheet, Quick Reference Guide, and Safe Imager
Note: For detailed information and safety symbols on this instrument, refer to the iBright
Modes
Invitrogen
™
iBright
™
Imaging Systems allow users to image in a mode specific to a sample type. Each mode is optimized to produce a high quality
image for further analysis and data collection.
Chemi Blots
Mode to image chemiluminescent Western blots.
Fluorescent Blots (FL1500 model only)
Mode to image fluorescent Western blots using a single channel or up to 4 channels using excitation wavelengths of 455-485 nm, 515-545 nm,
610-635 nm, 610-660 nm, and 750-768 nm with corresponding emission wavelengths of 510-555 nm, 565-615 nm, 675-720 nm, 710-730 nm, and
800-850 nm.
Nucleic Acid Gels
Mode to image DNA and RNA gels stained with fluorescent nucleic acid stains such as Ethidium Bromide, SYBR
™
SYBR
Gold and similar products.
Protein Gels (Protein Visible and Protein Fluorescence)
Mode to image visible, stained protein gels (using white screen) and fluorescent, stained, or labeled protein gels.
Note: Do not use the white screen for protein fluorescence.
Note: Stained or labeled protein on nitrocellulose or PVDF membrane should be imaged using Universal mode.
Universal
Mode to image samples containing multiple signals, such as chemiluminescence, fluorescence, and/or colorimetric stains. Image display is similar
to Fluorescent Blots and allows you to assign false color to any sample.
Gallery
Mode to retrieve, analyze, and manage images. Images are saved into a guest gallery or a registered user's gallery.
Get started
If the unit is off
If the unit is in sleep mode, touch the screen to activate the instrument.
Note: If the instrument does not respond to touch, ensure it is plugged in and turn on using the switch on the back of instrument. Continue to
step 1 below.
For Research Use Only. Not for use in diagnostic procedures.
™
Imaging System, Sample Stage/Turntable, White Transilluminator Screen, Sample Blot, Product Information
™
Viewing Glasses. Region-specific power cord shipped separately.
QUICK REFERENCE
™
Imaging Systems User Manual (Pub. no. MAN0018592).
™
Safe, SYBR
™
Green (I or II),