PROGRAMMING:
GT Entrance Station Addressing
Step 1:
Remove front panel from entrance station.
Step 2:
To enter programming, use a small screwdriver to push and release button under the rubber cap
on front of speaker module (GT-DA(-L)). The amber LED will begin blinking, then remain lit. Once
lit, the entrance station is in programming mode. The LCD will show "CONNECTING" while in
programming mode.
Step 3:
At residential/tenant station, push and release the TALK button to establish communication with
the entrance station in programming mode.
Step 4:
Scroll to the station number to be programmed or manually dial the number. When the residential/
tenant station number is displayed, push and release the Bell button
the residential/tenant station that is active. A blip tone will be heard.
Do not press and hold the Bell button as doing so will clear the memory for this address.
Step 5:
Turn off residential/tenant station (GT-1A, GT-1C7(-L), GT-1M3(-L): Push TALK again/ GT-2C(-L): Push OFF).
Step 6:
Repeat steps 3-5 for remaining residential/tenant stations.
Step 7:
To exit programming, push the button under the rubber cap on the GT-DA(-L) module again and
the amber LED will turn off. The system is now ready for use.
GT-DM(V)A Entrance Station Addressing
Step 1:
While in standby mode, enter # plus ID code (initial setting is
Step 2:
Use the up / down arrows and scroll to PROGRAMMING . Push the Bell button
programming mode. The amber LED will begin blinking, then remain lit. Once lit, the entry panel is
in programming mode. The LCD will show "CONNECTING" while in programming mode.
Step 3:
At residential/tenant station, push and release the TALK button to establish communication with
the entrance station in programming mode.
Step 4:
Scroll to the station number to be programmed or manually dial the number. When the residential/
tenant station number is displayed, push and release the Bell button
the residential/tenant station that is active. A blip tone will be heard.
Do not press and hold the Bell button as doing so will clear the memory for this address.
Step 5:
Turn off residential/tenant station (GT-1A, GT-1C7(-L), GT-1M3(-L): Push TALK again/ GT-2C(-L): Push OFF).
Step 6:
Repeat steps 3-5 for the remaining residential/tenant stations.
Step 7:
To exit programming, press the "X" button on the panel to return to the main menu (the amber LED
will turn off). Scroll to QUIT and press the "X" button again. The system is now ready for use.
GT-MK Security Guard Addressing
Step 1:
While in standby mode, enter # plus ID code (initial setting is
Use the up / down arrows and scroll to PROGRAMMING . Press the Bell button
Step 2:
programming mode. The LCD will show "CONNECTING" while in programming mode.
Step 3:
Pick up the handset on the GT-MK and leave off hook.
Step 4:
At residential/tenant station, push and release the TALK button to establish communication with
the GT-MK in programming mode.
Step 5:
Scroll to the station number to be programmed or manually dial the number. When the residential/
tenant station number is displayed, push and release the Bell button
the residential/tenant station that is active. A blip tone will be heard from the GT-MK handset.
Do not press and hold the Bell button as doing so will clear the memory for this address.
Step 6:
Turn off residential/tenant station (GT-1A, GT-1C7(-L), GT-1M3(-L): Push TALK again/ GT-2C(-L): Push OFF).
Step 7:
Repeat steps 4-6 for the remaining residential/tenant stations.
Step 8:
To exit programming, press the "X" button on the GT-MK to return to the main menu. Scroll to
QUIT and press the "X" button again. The system is now ready for use.
Transferring Data Between Entrance Stations
The residence / entrance station hand-shake information can be transferred between entrance stations and / or security
guard stations. The above hand-shake procedure must be done at one entrance station before the transfer can occur.
Refer to page 40 of the GT Series Installation Manual for this procedure.
Never do a transfer from an entrance station or security guard station that has not been addressed with residential/tenant stations.
ADDRESSING RESIDENCES VIA HAND-SHAKE METHOD (continued)
to assign the address to
*
1111). Re-enter ID code (initial setting is
to assign the address to
1111). Re-enter ID code (initial setting is
*
to assign the address to
*
1111).
to enter
1111).
*
to enter
7

Advertisement

loading

This manual is also suitable for: