INSTALLATION RECORD
Date of Installation:
Model Number:
Serial Number:
Tank-Cistern location:
Pump Setting:
Wire Gauge:
Riser Pipe Size:
I. INSTALLATION & OPERATING INSTRUCTIONS
It is important that all submersible pumps be installed by expe-
rienced persons and that all electrical connections comply with
the relevant electrical supply authority requirements.
The electrical connections and checks must
be made by a qualified electrician and
comply with applicable local standards.
These instructions are provided for guidance only, and assume
a familiarity with submersible pump installation and commis-
sioning procedures.
II. IMPORTANT!!!
The MINI-SUB is designed to pump effluent from a cistern. If
the fluid from the cistern or any plumbing system freezes, the
pump will be severely damaged.
The MINI-SUB is suitable to pump effluents that don´t contain
dissolved gases.
All the components which come into contact with water are
suitable to be used with drinking water.
The pump cannot be used for inflammable,
explosive or dangerous liquids.
III. INSPECT THE EQUIPMENT
Before going on the job, open all packages and check all equip-
ment to be certain everything is included and that no parts have
been damaged during shipment. The pump should be checked
for visible damage and nameplate inspected to be sure they are
the correct voltage and phase.
Ensure the motor voltage and phase
matches the supply voltages & phase.
INSTALLATION AND OPERATING INSTRUCTIONS
Above Ground
Below Ground
MINISUB
4" Effluent Bottom Suction Pump
Carefully store this manual.
These Instructions must be
delivered with the pump to the
operator.
WARNING: Read this manual
carefully. Failure to follow these
instructions and comply with all
applicable codes may cause
serious body injury and/or
property damage
IV. INSTALLATION
NOTE: FOR SEALING OF PIPE THREADS ONTO YOUR MINI-SUB
USE THREAD TAPE ONLY. DO NOT USE PIPE SEALING COM-
POUND AT ALL.
All pipe and fittings must be suited to the
maximum pressures available from the pump.
DANGER: Electric Shock Risk - When
installing, please ensure electro-pump is
disconnected from the electrical supply.
DANGER: Electric Shock Risk – MINI-SUB
pumps are not suitable for use in a swimming
pool and the relevant cleaning and servicing
operation.
1. Safety Cable
Do not use the electric cable to lower, lift or transport the pump.
As a precautionary measure, a safety line should be connected
to all pumps regardless of the type of drop pipe used. This line
should be fastened to the pump and at the top of the cistern.
2. Depth of Installation
Install the pump at least 8" from the bottom of the cistern to
avoid pumping sand, mud, etc.
Special feature of the MINI-SUB is that its body height is only
22" and it allows use of these pumps in cisterns with low water
depth.
It is advisable to install an automatic level controls to prevent
the electric pump from running dry and a pressure gauge to
verify its performance during operation.

Advertisement

Table of Contents
loading

Summary of Contents for Pearl MINISUB

  • Page 1 MINISUB 4” Effluent Bottom Suction Pump INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION RECORD Carefully store this manual. Date of Installation: These Instructions must be Model Number: delivered with the pump to the operator. Serial Number: Tank-Cistern location: Above Ground WARNING: Read this manual carefully.
  • Page 2: Electrical Connection

    3. Delivery Pipe Do not use metal drop pipe as the GROUND return under any circumstances. Use a delivery pipe with a diameter of 1 ½”. ATTENTION: Delivery pipes should be connected with the 3. Starting the unit utmost care. Make sure that all the connections fixed by means of threads are sealed.
  • Page 3: Operation And Maintenance

    2.1 Frost protection While MINI-SUB pumps do not require regular maintenance, it is a good practice to monitor the conditions and performance If the pump has to be stored after use, it must be stored in a of the pump. This diagnosis may be carried out by checking the frost-free location.
  • Page 4: Performance Chart

    IX. PERFORMANCE CHART MSP 07 MSP 05 WA TER SYSTEMS PD WATER SYSTEMS - 3000 W. 16 Ave. Miami, FL 33012. TEL: (954) 474 9090 FAX: (954) 889 0413 www.pdwatersystems.com | pdwatersystems...
  • Page 5: Instrucciones De Instalación Y Funcionamiento

    MINISUB 4” Effluent Bottom Suction Pump INSTRUCCIONES DE INSTALACIÓN Y FUNCIONAMIENTO REGISTRO DE LA INSTALACION Guardar este manual en un lugar seguro. Entregar estas Fecha de instalación: instrucciones al operador junto Número del modelo: con la bomba. Número de serie: ADVERTENCIA: Leer este Ubicación del tanque / cisterna:...
  • Page 6: Conexiones Eléctricas

    Una característica especial de la MINI-SUB es que su altura es protección externa adicional. de solamente 22” lo que permite su uso en cisternas con poca profundidad de agua. Los cables de extensión eléctricos tienen que tener una sección mínima de H07 RN_F. Proteger el conector y las conexiones de Se aconseja la instalación de controles de nivel automático para salpicaduras de agua.
  • Page 7: Funcionamiento Y Mantenimiento

    No operar la bomba si la válvula de salida despachan de la fábrica en un empaque adecuado adentro del está cerrada (cabeza cerrada) por más de cual deberían de permanecer hasta sus instalación. unos segundos. Si esto ocurre el motor se Después de haber comprado la bomba, revisar que no hubo sobrecalienta y se podrían verificar daños algún daño durante el transporte.
  • Page 8 IX. DIAGRAMA DE RENDIMIENTO MSP 07 MSP 05 WA TER SYSTEMS PD WATER SYSTEMS - 3000 W. 16 Ave. Miami, FL 33012. TEL: (954) 474 9090 FAX: (954) 889 0413 www.pdwatersystems.com | pdwatersystems...
  • Page 9: Installation

    MINISUB Pompe d’aspiration de bas effluents de 4” INSTRUCTIONS D’INSTALATION ET D’UTILISATION DONNEES D’INSTALLATION Conservez soigneusement ce manuel. Ces instructions doivent Date de l’Installation: être fournies à l’opérateur avec la pompe. Num.du modèle: Numéro de série: ATTENTION: Lisez attentivement ce manuel. Le non-respect de Empl.
  • Page 10: Connexion Électrique

    3. Tube de refoulement Toutes les pompes sont équipées d’un CABLE DE MASSE qui doit être connecté à Utilisez un tube de refoulement d’un diamètre de 1 ½ “. la terre de l’alimentation électrique entrante. ATTENTION: Les tubes de refoulement doivent être connectés avec le plus N’utilisez en aucun cas une colonne grand soin.
  • Page 11: Utilisation Et Maintenance

    2. Stockage et manutention Bien que les pompes MINI-SUB ne nécessitent pas d’entretien régulier, il est recommandé de surveiller les conditions et les La pompe ne doit pas être exposée à la lumière directe du performances de la pompe. soleil. Si la pompe a été déballée, elle peut être stockée Ce diagnostic peut être effectué...
  • Page 12 IX. TABLEAU DE PERFORMANCE MSP 07 MSP 05 WA TER SYSTEMS PD WATER SYSTEMS - 3000 W. 16 Ave. Miami, FL 33012. TEL: (954) 474 9090 FAX: (954) 889 0413 www.pdwatersystems.com | pdwatersystems...

Table of Contents