Summary of Contents for Mac Medical SS32

  • Page 1 SS Series Surgical Scrub Sinks Installation - Operation - Maintenance - Cleaning OSHPD Pre-Approved Read and understand all of the instructions and safety information in this manual before operating this product. MAN-004 Rev G © 2019 MAC Medical, Inc. 02/2019...
  • Page 2: Table Of Contents

    • SS32 - single basin • SS64 - double basin • SS96 - triple basin PURPOSE OF THIS MANUAL This user manual details the installation, operation maintenance and cleaning of the MAC Medical Surgical Scrub Sinks. This manual also contains general specifications, warnings and cautions. Table of Contents Warnings and Cautions Icon Key...
  • Page 3: Warnings And Cautions Icon Key

    MAC Medical or by or by other manufacturers, unless such a combination has been specifically endorsed by MAC Medical. MAN-004...
  • Page 4: General Specifications

    Instruction Manual General Specifications 1. Material: a. Sink basin and sink top: 14 gauge, 300 series stainless steel b. Sink skirt: 18 gauge, 300 series stainless steel. 2. Plumbing Material a. 1/2” copper or brass pipe b. Sink is furnished with in-line check valves on supply lines. 3.
  • Page 5: Inline Flow Switch Timer Controller (S0130-01) - Specifications, Switch Rating And Wiring Diagram

    Instruction Manual InLine Flow Switch Timer Controller (S0130-01) - Specifications, Switch Rating and Wiring Diagram NOTE: This feature (Fig. 1) is available only on Infrared Activated Scrub Sinks. This is an explosion-proof brass flow switch, actuation set point 0.50 GPM (1.89 LPM), and calibrated for water at standard conditions. It is used for accurate detection of excessive or insufficient flow rates. Service Compatible liquids Wetted materials Housing: brass; Piston: polysulfone; Spring: 316SS; O-Ring: Fluoroelastomer, Other: Epoxy. Temperature Limits -20 to 225°F (-29 to 107°C). Pressure Limits 1000 psig (68.9 bar). Accuracy ±10% of set point. Repeatability ±1%.
  • Page 6: Sink Dimensions - Ss32, Ss64, Ss96 Models

    Instruction Manual Sink Dimensions - SS32, SS64, SS96 Models Fig. 2: SS32 - single basin Fig. 3: SS64 - Dual Basin Fig. 4: SS96 - Triple Basin MAN-004 www.macmedical.com...
  • Page 7: Installation

    C. Optional wall mounting systems (in-wall chair carrier and pedestal style) and their mounting specifications shown in Fig. 15 (part S0001 for sink SS32), Fig. 18 (part S0002 for sink SS64), and Fig. 21 (part S0003 for sink SS96) on page 9 through page 11. 5. Install the soap spout on the sink (See page 8).
  • Page 8: Installing And Operating The Soap Spout

    Instruction Manual Installing and Operating the Soap Spout To prevent damage during shipment, the soap dispenser is stored inside the sink basin. Soap Dispenser tubing is also included. The dispenser spout should be installed before hanging the sink. 1. To install - remove the bushing (Fig. 8 - Item 3 shown in green). 2.
  • Page 9: Recommended Mounting Specifications - Ss32 - Single Basin

    Recommended Mounting Specifications - SS32 - Single Basin Fig. 13: Z bracket mounting locations - SS32 Fig. 14: In-line wall carrier mount - S0001 Fig. 15: In-line wall carrier mounting locations - SS32 For the assembly drawing of In-line wall carrier mount (S0001), see page 20. MAN-004...
  • Page 10: Recommended Mounting Specifications - Ss64 - Double Basin

    Instruction Manual Recommended Mounting Specifications - SS64 - Double Basin Fig. 16: Z bracket mounting locations - SS64 Fig. 17: In-line wall carrier mount - S0002 Fig. 18: In-line wall carrier mounting locations - SS64 For the assembly drawing for the In-line Wall Carrier Mount (S0002), see page 21. MAN-004 www.macmedical.com...
  • Page 11: Recommended Mounting Specifications - Ss96 - Triple Basin

    Instruction Manual Recommended Mounting Specifications - SS96 - Triple Basin Fig. 19: Z bracket mount locations - SS96 Fig. 20: In-line wall carrier mount - S0003 Fig. 21: In-line wall carrier mounting locations - SS96 For the assembly drawing of the In-Line Wall Carrier Mount (S0003), see page 22. MAN-004 www.macmedical.com...
  • Page 12: Connect Drain Pipe To Drain And Plumbing To Water Lines

    Instruction Manual Connect Drain Pipe to Drain and Plumbing to Water Lines Local building or plumbing codes may require modifications to the information provided. You are required to consult the local building and plumbing codes prior to installation. If the information provided here is not consistent with local building or plumbing codes, the local codes should be followed. This product must be installed by a licensed contractor in accordance with local codes and ordinances.
  • Page 13: Preventative Maintenance

    Instruction Manual Preventative Maintenance Every 6 months - 1. Check and adjust the temperature setting. Every 12 months - 1. Shut off water supply 2. Open up checkstops. 3. Clean strainers and check for free movement of checkstop poppet. 4. Replace seals if cracked, cut, or worn. 5.
  • Page 14: Replacement Parts For Manual Knee Operated And Infrared Self-Activated Sink Plumbing

    Instruction Manual Replacement Parts for Manual Knee Operated and Infrared Self-Activated Sink Plumbing Both plumbing configurations shown below indicate which parts are replaceable. See table below for replacement part numbers. Fig. 23: Infrared Self-Activated Sink Plumbing Fig. 22: Manual knee operated sink plumbing Item # Description Knee Operated Part # Infrared Activated Part # Spout for both knee operated or infrared activated plumbing SS0132-01 Thermostatic Mixing Valve for both knee operated or infrared activated plumbing...
  • Page 15: Plumbing Access ( Manual Knee Operated Sinks Only)

    Instruction Manual Plumbing Access ( Manual Knee Operated Sinks Only) 1. Open the knee panel door by depressing the latch at the bottom of the panel door (Fig. 24). 2. Swing the door fully open to access the hinges (Fig. 25). 3.
  • Page 16: Instructions For Cleaning Stainless Steel Surgical Scrub Sinks

    Instruction Manual Instructions for Cleaning Stainless Steel Surgical Scrub Sinks Stainless steel sinks must be cleaned on a regular basis to prevent any unnecessary damage to the stainless steel surfaces. When cleaning Ssainless steel sinks, make sure to use the proper approved cleaning agents and cleaning materials.
  • Page 17: Optional Ir Timer Assembly

    Instruction Manual Optional IR Timer Assembly An electronic IR Timer Assembly (S0202-SST-KT) can be purchased and installed on Infrared Activated surgical scrub sinks. The installation would require some modification of the sink top in order to install. Installing Optional Electronic Sink Timer Display 1. To mount the timer housing on the sink top, Fig.
  • Page 18: Timer Operation Display And Programming

    Instruction Manual Timer Operation Display and Programming EAGLE SIGNAL VEEDER-ROOT 345678 1. Time Display 3. Next/Reset Key 2. Down Key Time Display: Accumulates time when the timing start input is active. Timing will not take place when the external or front panel reset is active. The leftmost digit is the time value legend. Down Key: When the program input is active this key is used to scroll through the menu items.
  • Page 19: Timer Battery Replacement

    Instruction Manual Timer (S0050)- Specifications and Terminal Connections The timer is an Elapsed Time Indicator which is powered by an internal 3 volt lithium battery. It comes pre- assembled in its housing and ready for mounting to the sink. Specification Description Start/Stop Input NPN, Contact Closure; Accumulates time when connected to common; Low State: < 1.0 VDC, High State: > 2.0 VDC (28VDC max) Security Input Allows access to panel reset and programming features Remote Reset Input NPN or Contact Closure to common; level sensitive Power Source Single or dual 3V Lithium battery; typical 5 years life w/single battery, 10 years w/dual batteries Ranges & Resolution Seconds, minutes to 1/10, hours to 1/10,hours: minutes: seconds Display 12mm high, Supertwist LCD; 7 digits; “Low Bat” indicator...
  • Page 20: In-Line Wall Carrier Mount Assembly - Single Basin Sinks ( Part #S0001)

    This drawing shows how the in-line wall carrier for single basin scrub sinks is assembled. NOTE: To ensure stability, MAC Medical recommends that the In-line Wall Carrier Mount Assembly be tied into the existing wall support structure. All applicable local and state building codes should be adhered to when mounting this unit.
  • Page 21: In-Line Wall Carrier Mount Assembly - Dual Basin Sinks (Part #S0002)

    This drawing shows how the in-line wall carrier for dual basin scrub sinks is assembled. NOTE: To ensure stability, MAC Medical recommends that the In-line Wall Carrier Mount Assembly be tied into the existing wall support structure. All applicable local and state building codes should be adhered to when mounting this unit.
  • Page 22: In-Line Wall Carrier Mount Assembly - Triple Basin Sinks (Part #S0003)

    This drawing shows how the in-line wall carrier for triple basin scrub sinks is assembled. NOTE: To ensure stability, MAC Medical recommends that the In-line Wall Carrier Mount Assembly be tied into the existing wall support structure. All applicable local and state building codes should be adhered to when mounting this unit.
  • Page 23: Limited Lifetime Warranty

    UNLESS EXPRESSLY SET FORTH IN THIS WARRANTY, THERE ARE NO OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, OF FITNESS AND / OR MERCHANTABILITY OR ANY OTHER WARRANTY IMPLIED BY CUSTOM, USAGE OR COURSE OF DEALING. Liability of MAC Medical under this warranty is limited to the repair and / or replacement of any products. MAC Medical specifically excludes and disclaims any responsibility for any incidental or consequential damages claimed to have arisen from any defect in workmanship or materials. No representative has any authority to change or enlarge the above warranty or MAC Medical liability.