Auto-Shutoff with Optional Accessory Board/AquaLink
¾ hp Motor or Hydraulic Motor
Option 1: Auto-shutoff mounted outside housing.
POOL
#8 Bonding Wire
Both Ends
COVER HOUSING
Auto-Shutoff with Accessory Board/
¾ hp Motor or Hydraulic Motor
(Optional) --
POOL
COVER HOUSING
Auto-shutoff
#8 Bonding Wire
(Both Sides)
Option 1:
Key Switch 5v
Conduit with (3)
18 AWG Identified
Wires for Low
Voltage Key Switch
OR
Conduit with (4)
14 AWG Wires
For Power and (3)
18 Awg for Sensors
MOTOR
J-box
36" of Waterproof Flex Conduit
with 1/2" NPT Water Tight
Connector, Extend (4) 14 AWG
Wires 8" Past Conduit End
AquaLink
Green
Red
LED
LED
CoverLink Wireless
Control Pad
Receiver
AS
Antenna
36" of Waterproof Flex Conduit with 1/2"
NPT Watertight Connector for 14 Awg
Wire Extended 8" Past Conduit End
All diagrams are for general information. Consult installation instructions for details.
®
Option 2:
Green
Red
LED
LED
CoverLink Wired Control
Conduit with (4) 18 AWG (min)
Identified Wires for CoverLink
Wired Control
ACC
Optional Accessory Board or AquaLink
Conduit with (4) 18 AWG Wires
AS
Install auto-shutoff away from cover housing
in or by equipment room or equipment pad
14 AWG under 50ft
12 AWG over 50ft
Dedicated
GFCI
Conduit for Main Power with (3)
14 AWG Identified Wires
(Hot, Neutral, Ground)
®
and Wireless
ACC
Optional Accessory Board or AquaLink
Conduit with (4) 18 AWG Wires
Install acc board away from cover housing
in or by equipment room or equipment pad
Dedicated
GFCI
14 AWG under 50ft
12 AWG over 50ft
Conduit for Main Power with (3) 14 AWG
Identified Wires (Hot, Neutral, Ground)
All switches/control pads must
be mounted in full view of the
cover operation.
050275 or 050276
Hydraulic 1-1/2 hp motor
Hydraulic Pump Unit
above ground level.
electric 3/4 hp motor
All control pads must be mounted in
full view of the cover operation. Install
the accessory board in or by the
equipment room or equipment pad,
away from the cover housing.
050275 or 050276
above ground level.
Hydraulic Pump Unit
electric 3/4 hp motor
Hydraulic motors
must be mounted
Hydraulic motors
must be mounted
6
Need help?
Do you have a question about the Save-T 3 and is the answer not in the manual?