D. Connecting to a Viking 1600-IP-EWP Series VoIP Emergency Phone
Step 1.
Mount the PB-1 using the supplied foam tape.
Step 2.
Connect the RJ11 plug on the supplied cable to the PB-1.
Cut the PB-1 cable at the white connector, discard the connector and
Step 3.
mic.
Cut the black and red wires leading to the LED from the 1600-IP Series
Step 4.
board, leaving at least 1 inch of wire at the connector.
Attach the black wire from the board to the black wire from the PB-1
Step 5.
using a gel-filled butt connector (do not strip prior to inserting).
Step 6.
Attach the red wire from the board to the yellow wire from the PB-1.
Cut the two black wires leading to the switch from the 1600-IP Series
Step 7.
board, leaving at least 1 inch of wire at the connector.
Attach one black wire to the red wire, and one to the green wire from the
Step 8.
PB-1 (non-polarity sensitive).
Turn speaker mode to Off/Silent Monitor in IP Programming. See the
Step 9.
1600-IP Series Product Manual, DOD# 255.
Step 10. Connect the LAN with PoE cable to the RJ-45 jack.
PB-1
to PB-1
1600-IP-EWP Series Circuit Board
Switch Wires
Green
Black
Red
Black
+ Yellow
+ Red
- Black
- Black
5
LED Wires