Download Print this page

Installation - Viking PB-1 Product Manual

Panic button kit

Advertisement

A. Connecting to a Viking 1600A Series Analog Emergency Phone
Step 1. Mount the PB-1 using the supplied foam tape.
Step 2. Connect the RJ11 plug on the supplied cable to the PB-1.
Disconnect the installed white connector from the 1600A Series
Step 3.
Emergency Phone board.
Remove the 1600A Series Emergency Phone board and then remove the
Step 4.
installed mic by carefully pulling it out of the black plastic mic mount.
Place the mic from the PB-1 cable into the mic mount and replace the
Step 5.
1600A Series Emergency Phone board.
Connect the white connector on the PB-1 cable to the 1600A Series
Step 6.
phone board.
Connect the phone line to the red and green wires from the 1600A Series
Step 7.
Emergency Phone board.
Mic
PB-1
to PB-1
Connect to
phone line

Installation

White
Connector
Red
Green
2
1600A Series Circuit Board