Section 2 Goodrich Stormscope Interface; Goodrich Stormscope Description; Power-Up Self-Test; User-Initiated Test - Garmin 400 Series Pilot's Manual

Non-waas; display interfaces
Hide thumbs Also See for 400 Series:
Table of Contents

Advertisement

SECTION 2 GOODRICH
STORMSCOPE INTERFACE

GOODRICH STORMSCOPE DESCRIPTION

NOTE: The Stormscope is not intended for
hazardous thunderstorm penetration. Displayed
weather information is approved for weather
avoidance only. Refer to the WX-500 User's
Guide for a detailed description of Stormscope
operation.
The Goodrich STORMSCOPE WX-500 Series II
Weather Mapping Sensor is a passive weather avoidance
system that detects electrical discharges associated with
thunderstorms within a 200-nm radius of the aircraft. The
STORMSCOPE measures relative bearing and distance
of thunderstorm-related electrical activity and reports
the information to the display. Interfaces are currently
only available for the WX-500 Series II STORMSCOPE
System.

Power-Up Self-Test

The power-up self-test (Figure 2-1) ensures that the
WX-500 functions are operating properly. An error
message is displayed on the Message Page if data is no
longer being received.
190-00140-10 Rev. E

User-Initiated Test

In addition to the power-up test, the WX-500 performs
a continuous self-test.
performed several times per minute. A user-initiated test
can also be performed. The WX-500 Pilot' s Guide lists all
of the possible faults, probable causes, and recommended
actions if system failures are noted.
Performing a user-initiated test:
1)
From the default Nav Page, turn the small right
knob to select the Weather Page.
Press the MENU Key to display the Page
2)
Menu.
3)
Turn the small right knob to select 'Self-Test?'
(Figure 2-2).
Press the ENT Key.
4)
400/500 Series Display Interfaces
SECTION 2
STORMSCOPE INTERFACE
Figure 2-1 Stormscope Power Up Page
This continuous self-test is
Figure 2-2 Weather Page Menu
2-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

500 series

Table of Contents