Control Panel Operation Instructions - Friedrich Kuhl SS08 Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

Control Panel Operation Instructions

SYSTEM - The
button allows you to sequentially select up to four
SYSTEM
modes of operation:
AUTO
Not available on some models
- AUTO -
COOL
Not available on some models
HEAT
FAN ONLY
AUTO MODE
- AUTO -
AUTO FAN
COOL MODE
AUTO FAN
HEAT MODE
AUTO FAN
FAN SPEED - Depending on your model, the
When fan speed AUTO FAN mode (SYSTEM mode AUTO, COOL or HEAT) is selected, fan speed automatically varies depending on the difference between
the unit's set point on the control panel and the actual room temperature. When the system detects a wide difference between the set point and the actual
room temperature the fan speed increases to HIGH for a period of time. The fan speed decreases, in step, as the temperature difference decreases. When the
room temperature matches the system's set point, fan speed returns to the original setting.
F
SET POINT
FRR204
F
SET POINT
FRR103
F
SET POINT
FRR104
N
button allows you to toggle between four or five modes of operation: LOW, MEDIUM, HIGH and AUTO.
FAN
SPEED
FAN ONLY MODE
When in the
- AUTO-, COOL
you can also select FAN MODE, FAN SPEED, TIMER SCHEDULE,
. The SYSTEM MODE does not change.
and
FAN MODE – The
button allows you to select between
F A N
MODE
modes.
CONTINUOUS
AUTO FAN (No Cooling Demand)
AUTO FAN
When in the
mode, the fan only
AUTO FAN
a demand to cool or heat the room. Note: the fan is off (no fan speed icon),
indicating no command for cooling or heating.
AUTO FAN (Cooling Demand)
AUTO FAN
System has a demand for cooling. The fan is operating at a medium speed.
or HEAT
or FAN ONLY
mode,
AUTO FAN
F
SET POINT
FRR112
operates when the system has
F
SET POINT
AUTO
AUTO
FRR105
and
FRR106
11