Advertisement

Quick Links

ekey home
OPERATING INSTRUCTIONS
en

Advertisement

Table of Contents
loading

Summary of Contents for eKey home KNX RS-485

  • Page 1 OPERATING INSTRUCTIONS...
  • Page 2: Table Of Contents

    Commissioning ................7 Use ....................8 Configuring in a KNX system ............8 Use with ekey home control panel mini .......... 9 Use with ekey home control panel WM/IN ........10 Use with ekey home control panel DRM ........10 Use with ekey multi control panel DRM ........
  • Page 3: General

    Warranty and The version of our general terms and conditions in force on the date of manufac- purchase shall apply. See http://www.ekey.net. turer's guarantee Notices, symbols, and abbreviations NOTICE Denotes additional information and useful tips.
  • Page 4 Engineering tool software; software used for planning and configuring home automation systems with KNX bus system Finger scanner integra; ekey control panel model Name given to a field bus (data transmission facility) for home automation systems Wall-mounted; ekey control panel model...
  • Page 5: Safety Information

    Failure to do so will create a risk of fatal electrocution. Only certified electricians are authorized to carry out the electrical installation work! Tamper- Mount the ekey home converter KNX RS-485 in a secure internal area in proofing the distributor. This prevents tampering from the outside. Product description...
  • Page 6: Scope Of Delivery

    Function of the ekey home converter KNX RS-485 product The ekey converter KNX RS-485 functions exclusively with the ekey home and ekey multi biometric access control systems from ekey. The ETS5 software for planning and installing KNX systems is used to configure the ekey home converter KNX RS-485.
  • Page 7: System Identification

    System identification The ekey converter KNX RS-485 can be operated using different ekey access control systems. Before you begin the commissioning process, determine which access control system you have. This is indicated by the ekey control panel: ekey home control panel mini 1 ekey home control panel mini 2 See Use with ekey home control panel mini, page 9.
  • Page 8: Installation

    Wire the system in accordance with the supplied wiring diagram. NOTICE The wiring diagram displays the wiring of the ekey home converter KNX RS-485. Refer to the wiring diagram for the finger scanner for the wiring of the ekey home finger scanner and the lock.
  • Page 9: Use

    Up to 10 events can be triggered. These events are referred to as “ekey Event 1” to “ekey Event 10”. Every identified finger can trigger an event. You can set the following functions for “ekey Event 1” to “ekey Event 10”: Function Settings...
  • Page 10: Use With Ekey Home Control Panel Mini

    NOTICE No settings need to be adjusted for this function in the ekey system (ekey control panel). You can set the following functions for the ekey event “Security”:...
  • Page 11: Use With Ekey Home Control Panel Wm/In

    DRM 2 panel DRM NOTICE In order to configure the ekey home control panel DRM for use with the ekey converter KNX RS-485, please see the ekey home CP DRM operating instructions. Activating KNX...
  • Page 12 Y. CV KNX available: Y E01: F00 E02: F01 E03: F02 E04: F03 Press until the desired KNX settings ekey Event (E01–E10) is CV KNX available: Y E01: F00 selected. E02: F01 E03: F02 E04: F03 Press KNX settings...
  • Page 13 Delete user Fair mode Settings Reset The ekey home control panel DRM is now ready for operation with the ekey converter KNX RS-485. NOTICE If you do not wish to give the ekey Events 1-10 (E01-E10) descriptive names, then you can skip steps 7 to 12. Assigning descriptive names is helpful when carrying out further configurations of the system.
  • Page 14 Swipe your finger. Save user -------1-------- -------1-------- -------1-------- -------1-------- -------1-------- -------1-------- The ekey events “Security” and “Unknown” do not need to be configured in the ekey home control panel DRM. They are automatically triggered when the conditions are met. en│13...
  • Page 15: Use With Ekey Multi Control Panel Drm

    DRM 4 multi control panel DRM NOTICE In order to configure the ekey multi control panel DRM for use with the ekey converter KNX RS-485, please see the ekey multi CP DRM operating instructions. Activating KNX When operating the ekey converter KNX RS-485 with the ekey multi control panel DRM, the KNX function must be activated.
  • Page 16 E03: EXIT E04: F03 Press three times to Enroll user Delete user return to the main menu. Logging Special mode Settings Reset The ekey multi control panel DRM is now ready for operation with the ekey converter KNX RS-485. en│15...
  • Page 17 Configuring KNX ekey events 1-10 are assigned to a finger and a finger scanner via the SAVE USER process (see ekey multi CP DRM operating instructions, section SAVING USERS). In the storing process, the ekey event is assigned after selecting the user, key, and finger.
  • Page 18: Error Displays And Troubleshooting

    Finger ----------X---- --------------- --------------- The ekey events “Security” and “Unknown” do not need to be configured in the ekey multi control panel DRM. They are automatically triggered when the conditions are met. Error displays and troubleshooting Display Meaning...
  • Page 19: Maintenance

    All content, artwork, and any ideas contained in these operating instructions are subject to applicable copyright laws. Any transmission, relinquishment, or transfer of this content or parts thereof to any third party requires the prior written consent of ekey biometric systems GmbH. Translation of the original documentation. 18│en...
  • Page 20 Via Copernico, 13/A, I-39100 Bolzano Tel.: +39 0471 922 712 italia@ekey.net ID224/517/0/369: Version 2, 2016-06-27 Media Center ID: 3012 www.ekey.net Made in Austria ekey biometric systems GmbH operates a quality management system in compliance with EN ISO 9001:2015 and is certified accordingly.

Table of Contents