Siemens Sinumerik 840D sl Diagnostic Manual page 1028

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

List of Action Numbers
Example:
An interrupt interrupts the current program execution.
Other higher priority interrupts interrupt the previously activated
ASUB program execution.
2. The channel is active (program running, block search, loading machine data)
3. A channel has left the mode group on account of an interrupt.
4. Overstoring
Possible actions:
1. Cancel the program with the Reset button
2. Cancel the program with the Reset button
or stop the program (not with block search, loading machine data)
3. Cancel the program with the Reset button or wait until the interrupt has finished.
4. Deselect overstore
No. 8
Definitions:
Select overstore (PI command)
Should not occur in any alarm
No. 9
Definitions:
Deselect overstore (PI command)
Should not occur in any alarm
No. 10
Definitions:
Execute an "ASUB" user interrupt.
(VDI signal, ASUB interface, digital-analog interface)
Alarms can be switched on by machine data "HW_DEBUG_MASK" (for test purposes only).
Not permitted if:
1. The channel is active on account of block search or loading machine data
2. The channel has stopped, and the ASUB "ASUP_START_MASK" has to be started,
and the current block cannot be reorganized.
3. Reference point approach has not yet been made
Possible actions:
1. Wait until block search or loading machine data has finished,
or cancel the program with the Reset button.
2. Activate block change until NC block can be reorganized
3. Execute reference point approach, or this status can be
ignored by means of machine data "ASUP_START_MASK".
No. 11
Definitions:
Execute an "ASUB" user interrupt with fast retraction.
(VDI signal, ASUB interface, digital-analog interface)
as INTERRUPT
No. 12
Definitions:
Execute an "ASUB" user interrupt at the block boundary.
(VDI signal, ASUB interface, digital-analog interface)
as INTERRUPT
No. 13
Definitions:
Execute a fast retraction
Should not occur in any alarm
No. 14
Definitions:
Move tool (only with tool management) (PI command)
Should not occur in any alarm
3-1028
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG 2009 All Rights Reserved
03/2009

Hide quick links:

Advertisement

Table of Contents
loading