DRINKING WATER SYSTEM 3 (MODEL UCS3)
USER MANUAL
Thank you for purchasing one of our ENVIROGARD / Rainfresh Water Filters.
We are committed to ensuring that you are totally satisfied.
If you have any problems, don't go back to the store - please contact us !
QUESTIONS
8:30 AM to 5:00 PM EST)
A. Introduction........................................... 2
B. Safety Instructions ................................. 2
C. Technical Specifications ......................... 2
D. Installation ............................................. 3
a. Mounting the faucet ................. 3
b. Mounting the unit ..................... 3
c. Connecting the faucet ............... 4
d. Installing supply valve ............... 4
e. Start-up ..................................... 5
F. Maintenance ....................................... ...... 6
G. Troubleshooting .................................... 7
H. Parts List ............................................... 8
I.
Warranty .............................................. 8
Most issues can be resolved over the phone.
Canada Toll Free
1800 667 8072
Toronto and Area
(905) 884 9388
(Mon to Fri
CONTENTS
Tested and Certified by CSA International to CSA Standard B483.1, to NSF/ANSI Standard 53
for reduction of Lead, VOC, Cyst (e.g. Cryptosporidium & Giardia) and lindane, to NSF/ANSI
Standard 42 for reduction of chlorine, taste & odour, and to NSF/ANSI 372.
The standards referenced above evaluate products for use with disinfected waters.
_______________________________________________________________________________
Additional testing and verification for reduction of bacteria and particulates performed by
independent laboratory.
VIDEO INSTRUCTIONS
Or visit Rainfresh Youtube Channel

Advertisement

Table of Contents
loading

Summary of Contents for Rainfresh UCS3

  • Page 1: Table Of Contents

    DRINKING WATER SYSTEM 3 (MODEL UCS3) USER MANUAL Thank you for purchasing one of our ENVIROGARD / Rainfresh Water Filters. We are committed to ensuring that you are totally satisfied. If you have any problems, don’t go back to the store – please contact us ! Most issues can be resolved over the phone.
  • Page 2: Introduction

    This system is intended for use with cold water only. DO NOT INSTALL ON HOT WATER. o Only use Rainfresh filter cartridges with this unit. No other filter cartridge will function with this system. o Do not lubricate head O-rings with petroleum based lubricants. Only food-grade silicone (Dow 111 compound) should be sparingly used.
  • Page 3: Installation

    Set both cartridges aside in a safe place until final assembly. The following instructions are for installing the UCS3 system under the sink. It can also be installed on any other wall mounted remote location (such as basement or crawl space) from where tubing can be run to the faucet. The unit should not be installed more than fifteen feet away from the faucet.
  • Page 4: Connecting The Faucet

    AND REPLACEMENT. THE HIGHER AND CLOSER TO THE FRONT YOU MOUNT THE UNIT THE BETTER FOR REGULAR MAINTENANCE. 2. Partially screw the 3 mounting bracket screws (1011-0) into screw locations. Install mounting bracket and head assembly over screw heads and tighten screws. NOTE: If wall is too thin to accept screws then use round head nuts and bolts (not supplied) to mount bracket.
  • Page 5: Start-Up

    Step 5 : Start up  Remove wrapping from carbon cartridge (CF2) and carefully place it HEAD LUG into the sump (on the side of the inlet fitting – see page 8) with blue SUMP gasket facing up. Align the sump under the filter head and pull the GROOVE cartridge up with one hand and push blue gasket over boss of white head (see fig 9).
  • Page 6: Maintenance

    Cleaning 1M Ceramic Cartridge This cartridge is cleanable and reusable. The flow rate will gradually slow during use as contaminants build up on the ceramic surface. The flow is restored by scrubbing the surface of the cartridge as required using the abrasive cleaning pad (811-0) enclosed.
  • Page 7: Troubleshooting

    Ceramic cartridge is Replace cartridge immediately. Broken or cracked cartridges are not under warranty cracked or broken If the water from the UCS3 system tests positive for bacteria: Bad water test Inspect ceramic cartridge for cracks or breakage. Replace if necessary.
  • Page 8: Parts List

    Company's obligation under this warranty shall consist of repair, replacement or credit, at its option, of any part found by the Company inspection to be defective, provided that the product has not been misused, abused, altered or damaged as determined by the Company and provided that only approved Enivrogard/Rainfresh replacement cartridges have been used in the housings.
  • Page 9 MANUEL UTILISATEUR Nous vous remercions d'avoir acheté un de nos systèmes de désinfection ENVIROGARD/Rainfresh. Nous nous engageons à vous donner entière satisfaction. Si l'article vous cause un problème, ne retournez pas au magasin. Appelez-nous ! La plupart des problèmes peuvent être résolus par téléphone.
  • Page 10: Introduction

    Ce dispositif est conçu pour être installé sous l’évier avec un robinet distinct (fourni). UCS3 dispose d'un processus unique de filtrage en 4 étape (fig. 1). L’eau passe initialement à travers une cartouche filtrante au charbon actif (CF2) de haute qualité...
  • Page 11: Installation

    à l'assemblage final. Les instructions suivantes concernent l’installation du système UCS3 sous l’évier. Il peut également être installé à tout autre endroit distant à support mural (comme un sous-sol ou un vide sanitaire) d’où les tuyaux peuvent être acheminés jusqu’au robinet.
  • Page 12: Raccordement Du Robinet

    2. Installez le support et serrez les vis. REMARQUE: Si le mur est trop mince pour les vis, fixez le support avec des boulons et des écrous (non compris). Étape 3: Raccordement du robinet Mesurez la distance entre le robinet et le raccord de sortie (2554).
  • Page 13: Commencez

    Étape 5 : Commencez LUG DE LA TÊTE  Retirez la cartouche au charbon (CF2) de son emballage et insérez-la soigneusement dans le carter (sur le côté du raccord d’entrée – voir RAINURE DE page 8) avec le joint bleu dirigé vers le haut. Alignez le carter sous la tête CARTER de filtre et tirez la cartouche vers le haut avec une main puis poussez le joint bleu au-dessus de la tête blanche (voir fig.
  • Page 14: Utilisation Et Entretien

    Nettoyage de la cartouche en céramique 1M Cette cartouche est nettoyable et réutilisable. Lors de l’utilisation et à mesure que les produits chimiques s’accumulent sur la surface en céramique, le débit baissera progressivement. En nettoyant la surface de la cartouche à l’aide du tampon de nettoyage abrasif (811-0) fourni, vous pourrez retrouver un débit normal.
  • Page 15: Dépannage

    Remplacez la cartouche immédiatement. Les cartouches brisées ou fissurées ne sont pas couvertes fissurée ou brisée par la garantie. Si de l’au du système UCS3 se révèle positif pour les bactéries : Détection de la mauvaise qualité Inspectez la cartouche en céramique pour détecter des fissures ou des bris. Remplacez si nécessaire.
  • Page 16: Liste Des Pièces

    été modifié ou qu'il a été utilisé incorrectement ou de façon abusive, et pourvu que seules des cartouches Rainfresh aient été utilisées dans le filtre. Cette garantie ne couvre pas les cartouches de rechange.