Adding The Nxt To The Fujitrax Line Configuration - FujiFilm NXT Setup Manual

Scalable placement platform
Table of Contents

Advertisement

6. Setting Up Fujitrax Verifier
6. Specify the desired setting regarding quick verification.
Every time of removed feeder
Normal
7. Click [OK] and then reboot the computer to enable the new settings.
6.2.2

Adding the NXT to the Fujitrax line configuration

Follow the steps below when adding the NXT to the Fujitrax Verifier line configuration.
1. Open the Kit Line Configuration program by using the shortcut in the start up menu.
2. Enter "FUJIADMIN" as the user ID and then enter the appropriate password and service
name for the master database.
3. Click [OK] and the [Kit Line Configuration] window displays.
4. Select the Factory from the left pane and select [Add Line] from the [Edit] menu.
5. Specify the name of the NXT line in the [Line Name] data field and then specify the name
of the computer running the central server for the NXT in the [KITServer Hostname] data
field.
6. Click the new line in the left pane and the field updates to display the specified name.
7. Click [Add Machine] from the [Edit] menu. The right pane changes to display the data
fields for the new machine.
8. In the [Machine Nickname] field, specify the name of the NXT machine. The name
should match that used by Fuji Flexa for the machine.
9. Select [NXT] from the [Machine Type] drop-down list.
10.In the [Recipe Name, Top] and [Recipe Name, Bottom] fields enter the name of the
base. It does not matter that these settings are the same, because the NXT does not
use these settings. However, some value must be entered in these fields or an error will
occur when trying to save the line configuration.
11.Specify the board flow direction and the parts out settings in the appropriate fields.
12.Enter the name of the computer running the Central Server for this base in the [Central
Server Name] field. This should match the name used for the Kit Server for the line.
13.Enter the name of the computer running the Accessory Software server in the data field
for [Maintenance Server Name].
14.Click the new machine in the left pane and the machine name updates to display the
specified name.
148
Setting
Meaning
This specifies that a quick verify check of a
feeder and the parts must be performed before
the feeder is set in the machine. This is
required even if an ID (relationship) between the
feeder and parts already exists.
This specifies that a quick verify is not required
before a feeder is set in the machine, however
an ID (relationship) between the feeder and
parts set on the feeder must exist.