  • Page 1 ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement...
  • Page 2 LRF-3300S Ultrasonic Flowmeter Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp on type ultrasonic flowmeter is easy to install and no need to cut off the pipe, that saves you lots of troubles and cost.
  • Page 3: Specification

    LRF-3300S Ultrasonic Flowmeter Specification Flow range ±0.09ft/s ~ ±40ft/s (±0.03m/s ~ ±12m/s) Accuracy ±0.5% of reading (for ±1.5ft/s~±40ft/s) 0.1% of measured value Repeatability Linearity ±0.5% Pipe size DN25mm to DN5000mm (A pair of sensors) Analog output: 4~20mA, max load 750 Ω.
  • Page 4: Product Size

    LRF-3300S Ultrasonic Flowmeter Product size Transmitter size Transducer size 24 hours service: +86-186-5435-6933 Tel: +86-543-3382666 Fax: +86-543-3615999 E-mail: info@ultrasonicscn.com skype: Longruncn Website: www.ultrasonicscn.com...
  • Page 5: Product Weight

    LRF-3300S Ultrasonic Flowmeter Product weight Transmitter weight Transmitter weight Transmitter weight: 3.62kg Transducer weight Transducer weight: 1.69kg 24 hours service: +86-186-5435-6933 Tel: +86-543-3382666 Fax: +86-543-3615999 E-mail: info@ultrasonicscn.com E-mail: info@ultrasonicscn.com skype: Longruncn skype: Longruncn Website: www.ultrasonicscn.com Website: www.ultrasonicscn.com...
  • Page 6: Installation Site Selection

    LRF-3300S Ultrasonic Flowmeter Installation site selection The first condition for ultrasonic flow meter is the pipe must be full of liquid, the bubbles will greatly influence the accuracy of the measurement, please avoid the follow installation position: The suggestion installation area is as following: A is for upright pipeline, please notice the water direction is from the bottom to top.
  • Page 7: Measuring Principle

    LRF-3300S Ultrasonic Flowmeter Straight pipe demand We suggest avoiding the valve, T-branchpipe and elbows if the condition allow. Please satisfied the hardest positioninstallation requirements when you face more than one interfering resource. ≥10×DN ≥5×DN ≥20×DN Valve ≥20×DN T- branc h ≥15×DN...
  • Page 8 Max length to 1000ft (305m) Code Temperature sensor PT1000 Pt1000 temperature sensor Standard model: LRF-3300S - 2 - C1 - 030 Description: Standard ensure clamp-on type ultrasonic flowmeter, OCT, Relay, RS485, 4-20mA, 30ft cable. 24 hours service: +86-186-5435-6933 Tel: +86-543-3382666 Fax: +86-543-3615999 E-mail: info@ultrasonicscn.com...