Download Print this page
Savant CLI-8000 Quick Reference Manual

Savant CLI-8000 Quick Reference Manual

Thermostat processing unit

Advertisement

Quick Links

The Savant
®
CLI-8000 and CLI-8000A eight zone Thermostat Processing Units
(TPU) are at the heart of the Savant
communications with a number of remote sensors and optional user interfaces, the
Thermostat Processing Unit can manage up to eight heating, ventilation, and air
conditioning (HVAC) systems. The system is easily integrated with most leading
HVAC systems and can be designed as one part of a complete Savant
System solution.
The CLI-8000 version is configured using the keypad and display located on the front
panel.
The CLI-8000A version is configured using a climate application loaded onto an
Android™ based tablet (Android is a trademark of Google Inc). The tablet, which is
installed into the front cover of the TPU, incorporates a touch screen interface with an
elegant climate control application for setting up, viewing, and controlling each
climate zone independently.
Once installed and configured, either system the can be integrated to add monitoring
and control through an iOS device such as iPad
This Quick Reference Guide provides the information necessary to install the
CLI-8000/8000A as well as information on wiring to each of the optional and required
components of the Savant HVAC solution.
Box Contents
(1) CLI-8000 or CLI-8000A (Includes all mating connectors from front panel)
(1) Samsung Galaxy Tab 3 (CLI-8000A only)
(1) Quick Reference Guide (this document)
Related Components
Savant
®
Host
Savant
®
Controller SSC-0008-XX, SSC-0025-XX
External 120V AC to 24V AC Transformer, PWR-2440-XX
Optional Remote Sensors
Savant
®
SST-TEMP1 - Remote Indoor Sensor
Savant
®
SST-OTEMP1 - Remote Outdoor Sensor
Savant
®
CLI-THFM1 - Remote Humidity/Temperature Smart Sensor
Savant
®
CLI-PLEN1C - Commercial Plenum Sensor (Heat duct sensor)
Savant
®
CLI-PLEN1R - Residential Plenum Sensor (Heat duct sensor)
Savant
®
CLI-SLAB1 - SLAB Sensor (Floor Heating Sensor)
Note: Each zone on the CLI-8000/8000A supports communications with up to four
temperature sensors and two humidity sensors.
Specifications
Environmental
Environmental
Temperature
32° to 104°F
Humidity
10% to 90% Relative Humidity (non-condensing)
Dimensions and Weight
Dimensions and Weight
12.17 inches (309.12 mm) with cover
Height
Height
11.05 inches (280.67 mm) without cover
15.48 inches (393.19 mm) with cover
Width
Width
14.23 inches (361.44 mm) without cover
2.81 inches (71.37 mm) with cover
Depth
Depth
2.71 inches (68.83 mm) without cover
Weight
8.75 lb. / 4.0 kg
Power
Power
Power (Input)
24V AC (40VA) from external transformer
CLI-8000 = 12W @ 24V AC
Power Draw
Power Draw
(Maximum)
(Maximum)
CLI-8000A = 24W @ 24V AC
Cable Requirements
Cable Requirements
Relay Bank to
18 American Wire Gauge (AWG)
HVAC system
Standard HVAC wiring (RH, RC, W1, W, Y1, Y2, O, G, Aux)
Cable Requirements (Sensors)
Cable Requirements (Sensors)
Data Sensor
24 AWG (Cat 5) 600 feet (182 m) maximum (cumulative)
Bus (1-Wire)
Remote Sensor 24 AWG (Cat 5) 500 feet (152 m) maximum
Compliance
Compliance
Safety and
FCC Part 15
Emissions
RoHS
Compliant
Additional Info
Additional Info
RS-232
Baud Rate = 19200
009-1090-01
31314
Thermostat Processing Unit
(CLI-8000-00 / CLI-8000A-00)
Quick Reference Guide
®
Centralized Climate Control system. Through
®
®
or iPod
®
.
Control
Item
Item
Ethernet
A
HVAC Relays
B
RS-232
C
Station Bus
D
Console
E
DSB/1-Wire
F
Display/Keypad
G
Remote Sensors
H
Input Power
I
(Access)
Zone LEDs
J
Input Power
K
(24V AC)
Analog Control
L
USB
M
Smart Connect
N
Savant Confidential and Proprietary
Scan this QR code for additional
product information.
CLI-8000/8000A Front Panel View
Description
Reserved for Future Use
Each relay bank or zone gets wired to an HVAC
system. The CLI-8000/8000A supports wiring up to
eight individual HVAC systems.
Connect cable from the RS-232 port to a Savant
Controller. Communication between the controller
and the CLI-8000/8000A is achieved over the
RS-232 connection. RS-232 supports 19200 baud.
Reserved For Future Use
Mini USB (Mini-B) female connector (Serial UART);
Debug terminal
The DSB/1-Wire Connector connects to the Data
Sensor Bus, which is a serial bus based on the 1-
Wire protocol. The CLI-THFM1 smart sensor
communicates over the Data Sensor Bus through
this connection. Up to two smart sensors per zone
can be configured with a total of eight per system.
Monitors and configures the system. Use the keypad
to scroll through the available menus and configure
each zone.
Indoor, Outdoor, Slab, and Plenum two-wire
temperature sensors are connected here. A
maximum of two per zone is supported.
Remove the power input access screw and remove
the associated panel. This will give user access to
the power supply board for wiring the 24V AC input
power.
The Zone LED's indicate which zone has been
selected via the keypad for configuration.
System is powered by 24V AC power source. Power
cable is fed through ½ inch cable restraint (not
included) installed at bottom of box. Input power is
wired to a two position screw terminal block on the
power supply board.
Reserved for Future Use
The USB port connects to the optional Android™
based tablet. Communication between the tablet and
the CLI-8000A version of TPU is achieved through
the USB port.
Maintenance functions such as firmware upgrades
are achieved through the Smart Connect
connection. Requires SCA-CONF-XX or SCA-
CONFL-XX Smart Connect cable.
009-1090-01
CLI-8000-00
CLI-8000A-00
1
of 2

Advertisement

loading

Summary of Contents for Savant CLI-8000

  • Page 1 ® Control System solution. The CLI-8000 version is configured using the keypad and display located on the front panel. The CLI-8000A version is configured using a climate application loaded onto an Android™ based tablet (Android is a trademark of Google Inc). The tablet, which is...
  • Page 2 Wired to stage 1 heat terminal (W1) on HVAC system. Option 2: Optional Brackets (Surface Mount) 1. Screw the mounting brackets to the right and left side of the CLI-8000 using (4) W2 - Black Wired to stage 2 heat terminal (W2) on HVAC system.

This manual is also suitable for:

Cli-8000a