WALLACH ZOOMSTAR User Manual

Star colposcope with trulight

Advertisement

MODEL: STAR COLPOSCOPE
USER'S MANUAL
ZOOMSTAR
with TRULIGHT
COLPOSCOPE
TRISTAR
with TRULIGHT
COLPOSCOPE
REF: 906057T, 906057-40TU, 906140T
®
WALLACH
SURGICAL DEVICES
95 Corporate Drive
Trumbull, CT 06611 USA
Phone: (203) 799-2000
Fax: (203) 799-2002
www,wallachsurgical.com
EC REP
EMERGO EUROPE
Molenstraat 15
2513 BH, The Hague
The Netherlands
IMSC036-DFU • Rev. B • 10/14
Made in the USA

Advertisement

Table of Contents
loading

Summary of Contents for WALLACH ZOOMSTAR

  • Page 1 MODEL: STAR COLPOSCOPE USER’S MANUAL ™ ™ ZOOMSTAR with TRULIGHT COLPOSCOPE ™ ™ TRISTAR with TRULIGHT COLPOSCOPE REF: 906057T, 906057-40TU, 906140T ® WALLACH SURGICAL DEVICES 95 Corporate Drive Trumbull, CT 06611 USA Phone: (203) 799-2000 Fax: (203) 799-2002 www,wallachsurgical.com EC REP EMERGO EUROPE...
  • Page 2: Table Of Contents

    Assembly Instructions ................4 Operating Instructions ................4 Illumination ................... 5 Focusing Instructions ................5 Magnification ..................5 ZoomStar with Trulight, USB Video ............6 TriStar™ Assembly Instructions ................7 Operating Instructions ................. 7 Illumination ................... 7 Focusing the TriStar™ ................8 Accessories ..................
  • Page 3: Cautions

    A green LED is used to pick up blood vessels. The ZoomStar is mounted on a 5 point base for stability and maneuverability. IMSC036-DFU • Rev. B • 10/14...
  • Page 4: Assembly Instructions

    ASSEMBLY INSTRUCTIONS The ZoomStar™ with Trulight™ colposcope has three parts.  The Optics with eyepieces  Center Pole with the power control box  The Floor stand 1. Place the floor stand on the floor. 2. Insert the tapered end of the shaft on the bottom of the center pole into the center hole of the floor stand.
  • Page 5: Illumination

    Final magnification is determined by multiplying the eyepiece power times the microscope body power times the objective lens power. The Wallach ZoomStar with Trulight is normally shipped with 20x eyepieces and a 1/3 objective lens. Therefore, at the lowest setting of the magnification power knob on the microscope body (0.7), the final magnification would be:...
  • Page 6: Zoomstar With Trulight, Usb Video

    1. Install Sentech Image Viewing Software (StCamSWare) onto laptop desktop. (see Quick Start Guide IMSC031) 2. Attach Video ZoomStar microscope head to laptop via USB cable provided. 3. Turn on Colposcope. 4. Double click on the “STCamSWare” icon on the desktop.
  • Page 7: Tristar

    TriStar™ The TriStar™ with Trulight™ Colposcope is a highly versatile triple magnification stereoscopic colposcope. A magnification of 8x, 13x and 21x is obtained with the 3-step magnification changer. The field of view diameters are 24mm, 15mm and 9mm. A vessel delineation filter is incorporated to provide clear visualization of vascular patterns.
  • Page 8: Focusing The Tristar

    FOCUSING THE TRISTAR 1. Set the binocular eyepieces to “0” and adjust them to the proper interpupillary distance. 2. Peering through the eyepieces, move the entire TriStar backwards or forwards to get a “rough” focus on the target. (12” or 300mm from objective lens to target.) 3.
  • Page 9: Usb Video Attachment

    USB Video Attachment There is a video camera C-Mount Adaptor available to attach any analog or USB camera. (Please note that only one side of the C-Mount Adaptor can attach to the TriStar.) The instructions are as follows: 1. Attach the mounting ring to the camera. 2.
  • Page 10 3. Then attach the C-Mount Adaptor to the TriStar. 4. Plug in the S video cable if you have an analog camera. Next, plug in the power supply. Then plug the power supply into the wall. For a USB camera, plug the USB cable into the camera and the other end into the US port on the laptop or PC.
  • Page 11: Electrical

    When the colposcope is not in use, replace protective covers. Warranty Information The Wallach Star series of colposcopes is supported by a seven-year warranty from date of purchase covering any failure of the device due to defective workmanship or components, when used in compliance with the product’s intended use.
  • Page 12: Service And Repair

    Service and Repair Only Wallach Surgical Devices is authorized to service or repair this unit. If repair is attempted outside the factory, the warranty will be considered void. Wallach Surgical Devices is not responsible for any injury resulting from repairs made by other individuals or organizations not certified by Wallach Surgical Devices.
  • Page 13: Explanation Of Symbols

    Contact local WEEE disposal sites. ® Wallach is a registered trademark of CooperSurgical, Inc. Zoomstar™,Tristar™ and TrueLight™ are trademarks of CooperSurgical, Inc. ® Nikon is a registered trademark of Nikon Corporation in the United States and certain other countries.
  • Page 14: Specifications

    Specifications ZOOMSTAR™ SPECIFICATIONS  Nikon Continuous Zoom Optics 4.5x to 20x  Maximum height 51”; minimum height 40”  Overall weight 23 ½ lbs.  Center of column to end of leg 12”  Height of microscope to floor 36” to 46”...
  • Page 15: For All Star Colposcope Models

    For All Star Colposcope Models CLASSIFICATION Model Safety Class Star with Trulight Colposcopes  ALL models of Colposcopes have no Applied Parts.  Do not get fluid into the Colposcope. Should any liquid or solid object fall into the unit, unplug the unit and call Technical Support (866) 928-3211.
  • Page 16: Wallach Colposcopes Emc Compliance Information

    Guidance and Manufacturer’s Declaration – Electromagnetic Emissions The Wallach Colposcope is intended for use in the electromagnet environment specified below. The customer or the end user of the Wallach Colposcope should assure that it is used in such an environment. Emissions Test...
  • Page 17: Electromagnetic Immunity

    Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The Wallach Colposcopes are intended for use in the electromagnet environment specified below. The customer or the end user of the Wallach Colposcopes should assure that it is used in such an environment. IEC 60601 Compliance Electromagnetic Environmental –...
  • Page 18 To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Wallach Colposcopes are used exceeds the applicable RF compliance level above, the Wallach Colposcope should be observed to verify normal operation.
  • Page 19: Recommended Separation Distance

    Wallach Colposcopes. The Wallach Colposcopes are intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Wallach Colposcopes can help prevent electromagnetic interference by maintaining a minimum distance between...
  • Page 20 SURGICAL DEVICES 95 Corporate Drive Trumbull, CT 06611 USA Phone: (203) 799-2000 Fax: (203) 799-2002 www.wallachsurgical.com IMSC036-DFU • Rev. B • 10/14 Wallach Surgical Devices...

This manual is also suitable for:

Tristar

Table of Contents