Flight Medical Innovations Flight 60 iO2 Quick Reference Manual

Hide thumbs Also See for Flight 60 iO2:

Advertisement

Quick Links

Flight 60
Quick Reference Guide
Alarms & Power Management
Patient Monitoring
Controlled Parameters
Alarm Reset
ON/OFF
Nebulizer Port
*
Circuit Connectors
iO
®
This quick reference guide does not replace the Flight
60 Operator's Manual. The Flight 60 Operator's Manual
containing instructions, warnings, cautions and other
important information for the safe and proper use of this
product must be carefully read prior to
using the Flight60 ventilator.
Not yet cleared for use in the USA
*
2

Advertisement

Table of Contents
loading

Summary of Contents for Flight Medical Innovations Flight 60 iO2

  • Page 1 Flight 60 ® Quick Reference Guide Alarms & Power Management Patient Monitoring Controlled Parameters Alarm Reset ON/OFF This quick reference guide does not replace the Flight Nebulizer Port 60 Operator’s Manual. The Flight 60 Operator’s Manual containing instructions, warnings, cautions and other important information for the safe and proper use of this Circuit Connectors product must be carefully read prior to...
  • Page 2: Circuit Test

    Circuit TEST A Circuit Test is to be performed each time a Patient Circuit or components of a patient Circuit are replaced: Connect an adult (500 ml) test lung with a 90 degree elbow to the Flow Sensor’s patient side. Press the Technical button once, and then...
  • Page 3: Starting Ventilation

    Starting Ventilation Turn on the ventilator by pressing On/Off button Start ventilation by pressing and holding On/Off button for 2 seconds Stopping Ventilation/ Shutting Down On/Off Press the button once than again for 2 seconds...
  • Page 4: Parameters Set Up

    Parameters Set Up Trigger Pressure Support Volume/Pressure (sensitivity) setting setting Setting Ptrig PEEP PSV above peep Rate PCV above peep -2.0 Volume or Pressure Ventilation Screen 100% O2 Nebulizer ALARMS SIMV Selection Nebulizer* Ventilation Modes: ACMV, SIMV, To Alarms Screen 2 Minutes ON/OFF SPONT/CPAP, VtG/MVG, B-LEV...
  • Page 5: Extended Screen

    Extended Screen Altitude Non-Invasive MVG: Trigger Delay Inspiratory/ Compensation ON/OFF ON/OFF Expiratory Hold SIGH Altitude Comp. NPPV Trends Trigger Delay Maneuvers Rise Profile PSV Flow Term. PSV Ti Waveform VG mode Hold Length Square Flow Termination/Cycling - Limit the Square or Controls the length of from 10% to 70% of the inspiratory time in...
  • Page 6: Alarms Screen

    Trigger Mode NPPV Ptrig Alarms Screen Rise Profile PSV Flow Term PSV Ti Waveform ALARMS Square Screen Buzzer Level Apnea Interval Selection Setting Buzzer High Rate LOW Rate LOW Vte LOW Vti Apnea Interval LOW P HIGH P LOW MV HIGH MV FiO2 Low FiO2 High...
  • Page 7: Preset Load

    Preset Load Press the Technical button once, and Press Units LOW P Spont Language Show Circuit cmH2O English Info TEST then tap the Set Load on-screen button Show Log Show Log Goto Load Save Clock Alarm Change More... The control button turns orange, and a pop-up list with the numbers of the saved configurations appears.
  • Page 8 For Local Sales Contact: Flight Medical Innovations Ltd. www.flight-medical.com Local support: +1866 6587793...

Table of Contents